844-AB Sprayer control
24
Software 4.03
Liquid Density
To activate the Liquid Density setting, press
the Auto/ Man key. The D symbol will be
displayed at the top of the screen. The Liquid
Density that is programmed into the console
will also be displayed. To change density,
press the Plus or minus keys. Press the
Program key to accept the changes and return
to the Calculation step. The calculations will
use the Specific Gravity (Density). To revert
back to the calculation based on spraying
water, press the Auto/ Man key.
Figure 7-7: Liquid Density
1.28
1.28
1.28
1.28
D
1 2 3 4 5 6 7 8 9 10 11 12
NOTES:
If a liquid with a density other than water
will be sprayed, and that density was
programmed into the Specific Gravity
(Density) step during System
Setup mode, the “D” symbol must be
selected during Application Setup mode to
activate the alternate density.
Press the Auto/Man key during Application
Setup mode to activate the alternate
density. A “D” will be displayed at the top
of the console to indicate the alternate
density is active. This must be displayed
so that all calculations will use the
alternate density during operations . If the
“D” is not at the top of the display,
calculations will be based on water (1.00).
Figure 7-8: Liquid Density
9
9
9
9.0
.0
.0
.0
3.6
3.6
3.6
3.6
120
120
120
120
Km/h
BAR
1 2 3 4 5 6 7 8 9 10 11 12
3
3
3
3
L/Ha
D
After performing the calculations, advance to
the beginning of Application Setup mode to
make changes by pressing the Program key.
If no changes are necessary, Application
Setup mode is complete. Press and hold the
Program key for three seconds. Changes to
Application Setup mode will be stored in the
console’s memory.
NOTE:
The 844-AB console will not automatically
power down during Application Setup
mode. The system must be exited by
holding the Program key for three
seconds. A loss of power to the controller
during Application Setup mode will erase
all changes not saved to system memory.