background image

3

98-01467-EN R1

Radion 8140 automatic sprayer control

Information bar

The information bar displays:

►Application rate – displays the actual application rate or target 

application rate and accesses the preset target application 

rates

 

options menu.

►Selectable information – displays user-selected information 

including v

olume applied, flow rate, flow pressure, speed, total 

area applied and job number.

Figure 4: Information bar

Selectable information

Selectable information

Application rate

 Target application rate

 Manual mode

Regulation modes

Automatic regulation mode will automatically adjust the application 

rate based on the current speed in reference to the target rate. The 

target rate can be adjusted using the Boost/step percent increase/

decrease buttons 

5%

/

5%

 on the Operation menu. Preset 

application rates define up to three (3) target rates for product being 

applied per hectare/acre. These can be toggled using the Application 

rate section on the Information bar on the Operation screen. 
Manual regulation mode will retain an established regulation valve 

setting regardless of speed.  The regulation valve setting can be 

adjusted using the Regulation valve open/close buttons     on 

the Operation menu. 
1. From the Operation screen, press the OPTIONS tab   to display 

the Operation menu.

2. Select from:

 Auto reg 

 to change from Manual regulation mode to 

Automatic regulation mode:

 Man reg 

 to change from Automatic regulation mode to 

Manual regulation mode:

NOTE:  The Regulation button displays the regulation mode that may 

be selected not the active regulation mode.

Figure 5: Regulation options: Automatic / Manual

0%

Man

reg

5%

5%

Auto

reg

0%

Man

reg

5%

5%

Manual regulation mode

Manual regulation mode will retain an established regulation valve 

setting regardless of speed. 
To open/close the valve:
1. From the Operation screen, press the OPTIONS tab   to display 

the Operation menu.

2. Press the Regulation valve open/close buttons       to 

manually turn the valves on/off.

3. Press the Close menu button  .

Figure 6: Manual regulation mode

Auto

reg

Содержание RADION 8140

Страница 1: ...U S E R G U I D E RADION 8140 Automatic sprayer control Software version 1 05...

Страница 2: ...uto steering device is not designed to replace the vehicle s operator Do not leave a vehicle while the Radion 8140 is engaged Ensure the area around the vehicle is clear of people and obstacles before...

Страница 3: ...t application rates 4 3 SET UP THE MACHINE 5 Operation 5 Implement parameters 6 Section configuration 6 Nozzle preset setup 6 Establish nozzle presets 7 Calibrations 7 NO 4 START NEW JOB OR CONTINUE J...

Страница 4: ...et com Radion 8140 automatic sprayer control NOZZLE SELECTION 20 Selecting the current nozzle 20 Presetting nozzles 20 TANK 21 ALARM WARNING 21 PRESSURE GAUGE 22 BOOM SECTIONS SWITCHES 22 ALARM CONFIG...

Страница 5: ...one of up to the same number of sections on the boom and illustrated on the Operation screen Switches control individual boom sections On Flip the switch up Off Flip the switch down Master switch ope...

Страница 6: ...sure gauge displays current pressure range compared with recommended pressure range Droplet size displays selected droplet size Boom sections displays configured boom sections Spray status displays ac...

Страница 7: ...sing the Application rate section on the Information bar on the Operation screen Manual regulation mode will retain an established regulation valve setting regardless of speed The regulation valve set...

Страница 8: ...ETERS Job parameters configures the target application rate settings and current nozzle Selections are also active on the Operation screen 1 From the Home screen press the SETTINGS button 2 Press Job...

Страница 9: ...cts a regulation mode Calibrations establishes either manual automatic settings of the Implement speed sensor Flow sensor Liquid pressure sensor Fill flow sensor and Tank level sensor Alarms establish...

Страница 10: ...les in the current section number Copy section sets all Number of nozzles counts to the same count for all boom sections based upon the current Section number Section width displays the width for the...

Страница 11: ...tion of this guide 1 From the Home screen press the SETTINGS button 2 Press Machine 3 Press Calibrations 4 Select from Implement speed sensor establishes the wheel impulses over a specified distance F...

Страница 12: ...re Alarms Nozzle preset Minimum tank content Fill valve No pressure calibration Minimum tank content Nozzle series Automatic filling Section number Maximum pressure Flow pressure cross check Nozzle ca...

Страница 13: ...isplayed active on the Operation screen may be exported as a PDF report Job information includes Job number of information displayed Current date Applied area Volume of material applied Distance trave...

Страница 14: ...ic calibration Flow sensor The Flow sensor establishes the impulses per litre Establish the value manually or automatically calibrate the value Calibration number enter the amount of impulses counted...

Страница 15: ...d To cancel the calibration press Cancel RETURN arrow or the Home button Figure 21 Automatic calibration Liquid pressure sensor The liquid pressure sensor settings establish the maximum pressure limit...

Страница 16: ...hen complete Master switch status Pressure adjustment Shows if the Master switch is off or on Press the UP DOWN arrows to increase decrease the pressure until reaching and maintaining the reference pr...

Страница 17: ...flow meter is unknown or to make sure the value is correct Impulse count number of impulses calculated during automatic calibration Collected volume enter the collected volume Automatic calibration do...

Страница 18: ...tion settings can be exported to a USB drive and recalled for future use NOTE Manual calibration is not available for any Tank level sensor calibrations 1 From the Home screen press the SETTINGS butto...

Страница 19: ...screen The amount displayed is established in Settings OEM Tank setup Minimum tank content 1 Press Calibrate to record a new calibration value and finalise the calibration The low high graph should d...

Страница 20: ...press RETURN arrow or press the Home button Figure 33 Tank level sensor Tank shape Import export Tank level sensor calibration settings can be exported to USB drive and recalled for future use NOTE T...

Страница 21: ...displays current flow rate Flow pressure displays current flow pressure Speed displays vehicle speed Area applied displays applied area for the selected job number Job number displays the current job...

Страница 22: ...ly for the selected number These settings will be the same for all active jobs Range is 0 to 6 554 litres hectare Select target application rate 1 Press the Application rate section 2 Select one 1 of...

Страница 23: ...ent Increase decrease percentage 1 From the Operation screen press the OPTIONS tab to display the Operation menu 2 Press the Boost step percent increase decrease buttons 5 5 to adjust application rate...

Страница 24: ...les Nozzle preset setup establishes up to five 5 sets of nozzle options setting the nozzle type capacity low high pressure limit reference flow and reference pressure For more information see Settings...

Страница 25: ...ank sensor or Fill flow sensor is active Density type Density factor available when Density type is Fertiliser Desired content available when Tank sensor or Fill flow sensor is active Automatic fillin...

Страница 26: ...ange are directly associated with the current droplet sizes The droplet size displays as one 1 of eight 8 classification categories Table 1 Droplet size chart Category Symbol Colour code Extremely fin...

Страница 27: ...eck components and programming steps related to pressure Settings Machine Implement parameters Nozzle preset setup 2 15 Pressure too high Check components and programming steps related to pressure Set...

Страница 28: ...ctive companies or organizations Limitation of Liability TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED NO COPYRIGHT LIABILITY OR PATENT IS A...

Отзывы: