59
TROUBLESHOOTING FOR ELECTRICAL CONTROL PANEL,
SERVICE PART NO. 730155.
TROUBLE
PROBABLE CAUSE
REMEDY
Electric Starter Does Not Crank
Check to determine if crankshaft
Relieve load on crankshaft.
Engine
turns freely; if not, check for
Disengage associated
binding belts, pulleys, clutches,
equipment clutches, belts or
etc.
pulleys.
Check battery connections for
Correct problem.
corrosion and/or breaks.
Weak or bad battery.
Replace or charge battery if
less than 3/4 charged.
Push button starter switch.
Replace if inoperative. See
Service Instruction on preceding
pages.
Electric starter.
See troubleshooting chart.
Panel wiring.
Correct problem.
Starter Cranks Engine But Engine Toggle switch.
If inoperative, replace. See
Does Not Start
Service Instructions on
preceding pages.
Insure spade connectors are
Correct. See Service Instructions
secured to appropriate switch
on preceding pages. See
terminals.
“Engine Fails to Start”
Ammeter Does Not Show A Charge Weak or bad battery.
Charge or replace.
(If battery is fully charged,
ammeter will not show a charge)
Faulty wiring and/or connections.
Correct or replace.
Shorted or open alternator.
Replace.
Regulator-Rectifier.
Replace.
Ammeter.
Replace if inoperable. See
Service Instruction on preceding
pages.
Ammeter Shows A Discharge.
Broken wiring and/or insulation.
Correct problem.
Toggle switch.
Check and replace if inoperable.
See Service Instructions on
preceding pages.
Содержание HH100