Tecumseh CD454532EGH-S Скачать руководство пользователя страница 6

6

INSTALLATION INSTRUCTIONS

TO PROPERLY LOCATE THESE OUTDOOR CONDENSING UNITS, CAREFULLY 
CONSIDER THESE IMPORTANT FACTORS:

UNPACKING, LIFTING/HANDLING INSTRUCTION

Weight Of The Unit.

 If units are installed on the roof, their weight and weight 

distribution should be checked against the building specifications and the building 
codes.

Distance Of  The Unit

  to the refrigerated cabinet and power supply socket.

Space Around The Unit

 and in between adjacent units. This should consider 

prevention of the re-circulation of the air and ensure enough airflow through the unit. 
(Refer Drg.1 in page no. 4)

These distances should also provide enough room around the units so that 
enclosure panels may be removed and that adequate accessibility is provided to the 
compressor, electrical boxes and other controls for maintenance.

Orientation of the units should consider the prevailing wind direction. It is 
recommended not to position the units in such a way that the airflow direction 
through the unit faces to prevailing wind direction for the area. The units should be 
mounted securely on adequate rigid and leveled bases, to avoid improper 
lubrication conditions for the compressor. Never use the shipment pallet as a 
permanent mounting base. If vibrations is a concern, then proper vibration insulators 
should be installed under the mounting base.

 

 Don’t remove the carton box until the unit arrives at the destination.

 

 Verify the shipping symbols on the packing box are in right direction.

 

 Cut the packing straps and remove the packing carton box.
(refer the Picture-1  Picture-2)

 

 While lifting proper measures should be taken to protect the enclosure panels.

 

 Always keep the unit upright, laying the unit on its side or top may cause 
 the unit damage.

 

 Care should be taken to locate the center of gravity of the unit before lifting,

 

 as  the compressor is the heaviest part of the unit may not be located in the 

center of the unit base.

 

 Never lift or displace the units with enclosure panels removed.

A

 

ll the panels should be in place and properly tightened.

Содержание CD454532EGH-S

Страница 1: ...Outdoor Condensing Units www Tecumseh com INSTALLATION INSTRUCTION MANUAL...

Страница 2: ...E TESTING FOR LEAKS 12 13 SYSTEM EVACUATION AND SYSTEM CHARGING 14 15 APPROVED HERMETIC COMPRESSOR OILS SYSTEM START UP PROCEDURE 15 16 OPERATIONAL CHECKOUT PROCEDURE MAINTENANCE ODCU AND TROUBLE SHOO...

Страница 3: ...H S XX XX E 38 5 4 3 ODCU NOMENCLATURE ODCU EXPLODED VIEW ODCU PARTS LIST CONDENSER COIL RIGHT PANEL ELECL COVER LIFT HANDLE FRONT PANEL FAN GRILL FAN MOTER WITH BLADER RECEIVER COMPRESSOR FILTER DRIE...

Страница 4: ...2 53 1 670 607 300 520 1 2 53 1 1 670 607 300 520 5 8 53 670 607 300 520 5 8 53 A B C D DIMENSIONS ARE IN MM DIMENSIONS MINIMUM WALL CLEARANCES SUGGESTED FOR INSTALLATION UNIT MODEL CDUS4524EGE S CDU4...

Страница 5: ...538EGF S CDU4542EXG FB CDU4542EXG S LIQUID LINE FLARE NUT TYPE UPTO VERTICAL MOUNTING PITCH E DIAGRAM 2 2 975 810 400 675 395 5 8 3 8 68 2 975 810 400 675 395 5 8 3 8 75 2 975 810 400 675 395 5 8 3 8...

Страница 6: ...the units in such a way that the airflow direction through the unit faces to prevailing wind direction for the area The units should be mounted securely on adequate rigid and leveled bases to avoid i...

Страница 7: ...MOUNTING Make a concrete platform to the mounting dimension of M8 anchor bolt 4 Nos with M8 Plain washers Base surface should be leveled properly for mounting pitch dimensions refer drawing No 1 2 on...

Страница 8: ...18 8 0 65 2 6 900x360x805 1059x500x875 68 CDU Model Compressor Model Power Supply Cooling Capacity btu hr Nominal Current a Power Input w Max Refrigerant Chargable HP Pr Switch Cut In cut Out Bar LP...

Страница 9: ...ontrol all these units as per the application requirement That is solenoid valve for the liquid line Applicable for fully built models only Room thermostat is the scope of customer and installed by th...

Страница 10: ...DCU STANDARD 1 PHASE MODEL Legend COMP Compressor RU Potential relay F MOT Fan Motor CCH Crankcase Heater HP SW High Pressure Switch LP SW Low Pressure Switch LLSV Liquid Line Solenoid Valve E L N 1 2...

Страница 11: ...nside the tubes it is recommended to flow dry nitrogen through the tubing during the brazing operations Alight flow of about CFM is sufficient Assurance of adequate velocity thus ensuring oil return c...

Страница 12: ...100 free of leaks Use of electronic leak detection equipment is highly recommended due to its potential accuracy when used correctly in accordance with the manufacturer s instructions If trace amount...

Страница 13: ...g the system always use a pressure regulating valve on the nitrogen cylinder discharge The pressure regulator must be able to reduce the pressure down to 1 to 2 psig and maintain this pressure The reg...

Страница 14: ...ure related problems SYSTEM CHARGING Failure to properly charge the system can result in serious injury or death from explosion or fire Follow these precautions when charging a system Do not operate t...

Страница 15: ...an motor mounting screws fan blade tightening screw shroud electrical boxes etc Check that the safety and pressure controls are connected and set correctly Check that the suction and liquid Service va...

Страница 16: ...ed refrigerant charge and correct any probable malfunction observed Always re assemble the enclosure panels when operational check out procedure is completed Never leave loose or not properly tightene...

Страница 17: ...r if shipping damage is discovered If damages to the packing are obvious but no visible damage on the unit or the parts are noted then a report should be compiled and a claim for probable hidden damag...

Страница 18: ...d or fuse open or removed Compressor motor winding open or short Wiring improper or loose Compressor motor has a ground fault also known as short circuit to ground B COMPRESSOR NOT STARTING HUMS BUT T...

Страница 19: ...ut out due to Liquid line solenoid leaking Undercharge of refrigerant Restriction in expansion device REFRIGERATION ACCESSORIES INSTRUCTIONS FOR THE FILTER DRIER SOLDER TYPE Low voltage to compressor...

Страница 20: ...20 IINSTRUCTIONS FOR THE SIGHT GLASS SOLDER TYPE...

Страница 21: ...21 INSTRUCTIONS FOR THE SOLENOID VALVE SOLDERING TYPE...

Страница 22: ...22...

Страница 23: ...hile transportation If require additional wooden board to be nailed CONTACT INFORMATION Please write us back with your valuable Feedback to our sales representative The information in this booklet are...

Страница 24: ...Mumbai 400705 Ph No 022 65176929 Old No 37 New No 6 Arcot Road VADAPALANI Chennai 600 026 Supra CFA 23652244 23652300 4 2 1A Rustomjee Street Kolkata 700019 Ph No 033 24606026 Fax No 033 24606027 Gala...

Отзывы: