5) In configuration
B1-M2
, 1 bar (B1) + 2 fans connected (M1-M2), the positioning and connection of the fans must
absolutely respect what is shown in the image below:
ATTENTION:
incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
Connect the motor connector A, of the single fan, with the relative motor power
cable to the MOTORS POWER LINE output of the control box.
B1 bar motor power supply
After making all the connections of the individual fans, connect the 230Vac 50/60Hz fan lines
to the
MOTORS POWER SUPPLY
input
of both control boxes (B1-B2)
.
M1
M2
~ Brown
~ Blue
~ Brown
~ Blue
Connect the B motor connector of the single fan, with the relative digital cable motor signals to the MOTORS CONTROL
LINE output of the control box.
B1 bar digital connection:
M1
M2
1 White
2 Brown
3 Blue
4 Black
5 White
6 Brown
7 Blue
8 Black
6) In configuration
B1-M1
, 1 bar (B1) + 1 fan connected (M1), the positioning and connection of the fan must absolutely
respect what is shown in the image below:
ATTENTION:
incorrect positioning or
connection of the fans result in
anomalies in operation of the TRBH
system.
BOX B1
BOX B1