F4 group– Display parameters
Code
Parameter
Default
F400 Output frequency
F401 Setup frequency
F403 Output voltage
219
F404 Voltage of DC bus
300
F405 Input terminal signal
0
F409 Fault record 1
F410 Fault record 2
F411 Fault record 3
F412 Fault record 4
Example: Multi-speed
Parameter
F203 = 3
F202 = 2
F20 1= 1
Terminal
X3
X2
X1
F001, F005
0
0
0
F216
0
0
1
F220
0
1
0
F224
0
1
1
F228
1
0
0
F232
1
0
1
F236
1
1
0
F244
1
1
1
※
Process of setting to default (the factory setting):
Set F321 for 1
→
Press “Up” for 5 seconds
→
Show 2 on the display
→
Press “Enter”
→
Show “------“ on the display
→
complete
Note: Some default values will be the value with*