1.5.2 INSTALLATION AND FUNCTIONING OF THE APPLIANCE
1) Do not install and do not try to repair the appliance if it was damaged during
transport.
2) Do not connect the power cord to the power supply, unless specifi cally required.
3) In order to ensure the correct working of the device in safe conditions, it is ab-
solutely forbidden to expose the appliance to atmospheric agents and to direct
heat sources (Fig. 1). The temperature of the installation environment has to be
between 10 °C and 38 °C (50 °F – 100 °F).
4) Insert the plastic screws (Ref. D Fig.5) in the square holes of the conveyor (Ref.
E Fig.5).
5) Assemble the conveyor (Ref. E Fig.5) and fasten it turning the screws a quarter
of a rotation anti-clockwise (Ref. Q Fig.6) using the wrench supplied (Ref. P
Fig.6).
6) Minimum distances from the walls and characteristics of the tube (not supplied)
if you want to convey air.
CAUTION: Do not insert the fi lters in the tube or other elements which
could obstruct the air fl ow.
7) The appliance must be installed in a ventilated environment or combined with
a grow box. If installation is outside (Fig.11) or inside the grow box (Fig.12), a
tube (not supplied) can be connected to the conveyor (see Tab. 5-2) for hot air
evacuation.
8) Prepare the water tubes as follows:
8.1) If necessary, insert before the squeeze-tube clamp (Ref. P2 Fig.9) then the
cable-tie-wrap (Ref. P3 Fig. 8).
8.2) Insert the joint ( Ref. P4 Fig. 8) in the tube, and bring cable-tie-wrap on the joint
( Ref. P5 Fig. 8).
8.3) Fasten the joint clockwise (Ref. P7 Fig. 10), direct it as needed and tighten it .
8.4) When connecting the pipes, make sure that the pipe from the pump (not sup-
plied) and/or the fi lter assembly (not supplied with the unit) is connected in the
position indicated with IN (Ref. P8 Fig. 10), and that the return pipe is connected
to the hydroponic system in the position indicated with OUT (Ref. P9 Fig. 10).
9) Install the appliance in the chosen place allowing the visibility of the equipment.
10) Start the pump, if necessary reopen the squeeze-tube clamp (Ref. P6 Fig. 9)
Minimum distance from the walls
(Fig.7)
Air input side
50 mm – 1,97 in
Air output side
50 mm – 1,97 in
Tab. 1-1
Characteristics of the tube
Tube inner diameter 200mm (7.87in)
Maximum length of tube 2m (78in)
Maximum one 90° curve
Tab. 1-2