TECO TD-12M1 Скачать руководство пользователя страница 7

5

A dehumidifi er is not an air conditioner, but rather an appliance that is used to control relative humidity by 

reducing the moisture in the ambient air.  This is done by passing air through the dehumidifi er. When the air 

passes through the cooling elements within the appliance, it causes the excess moisture to condensate and 

safely drain into the water tank. The dry air is then passed through the condenser to warm slightly before 

returning it into the ambient air.

Positioning The Dehumidifi er

Moisture travels through the air much the same way scents and smells do. Because moisture moves with air 

fl ow,  position the dehumidifi er in a location that can draw the most air. The eff ectiveness will be increased 

when placed in a location where it is able to draw the most moisture from all directions and circulate the air 

around the room.

If you have an area or location that is specifi cally in need of dehumidifying, place the appliance in the 

aff ected area until the humidity is reduced, then relocate the dehumidifi er to a more central location for 

best air circulation.

When placing the dehumidifi er, ensure it is on a fl at and level surface. The dehumidifi er may vibrate or 

operate less effi

  ciently if the surface is not level.

The dehumidifi er is fi tted with castors for mobility purposes. If you wish to move the dehumidifi er, ensure it 

is fi rst switched off  and the water tank is emptied.

It is not recommended to connect the appliance to an extension lead. Ensure to place the dehumidifi er near 

to a fi xed power socket.

During operation, exterior doors and windows should be closed to ensure appliance effi

  ciency.

HOW DOES IT WORK?

Moist and 
humid air

Fig. 1

Dry and 
slightly 
warmer air

Fig. 2

Minimum 
clearance 
distances.

Side and 
back
clearance
≥40cm

Side and 
front
clearance
≥40cm

Top clearance
≥60cm

Содержание TD-12M1

Страница 1: ...DEHUMIDIFIER User s Manual Model TD 12M1 Please read these instructions carefully before using your dehumidifier After reading keep in a safe place for future reference ...

Страница 2: ......

Страница 3: ...pproved for use with non flammable R134a refrigerant The appliance is specifically constructed for domestic and light office use The appliance has not been designed or manufactured for professional use Teco declines all responsibility for damage deriving from improper use of the appliance The dehumidifier has undergone the necessary tests on the tightness of the refrigeration circuit and complies ...

Страница 4: ...Chapter Page No Safety Precautions 3 4 How does it work 5 Positioning the Dehumidifier 5 Part Identification 6 Control Panel 7 Operating instructions 7 Drainage 8 Maintenance 9 Troubleshooting 10 Specifications 11 ...

Страница 5: ...vices such as stoves fan heaters etc The plastic parts may melt causing fire Wipe dust off the power plug and insert the plug firmly into the power outlet socket If the plug is not fully inserted in the power outlet socket dust may gather on the connectors which in turn may cause fire and or electric shock Use 220 240V AC power outlet sockets with a current rating shown on the rating plate attache...

Страница 6: ... drain water continuously if there is a possibility that the temperature around the drainage hose field supplied could drop to freezing point Water inside the hose may freeze and prevent the water in the tank from flowing out The water may leak from the appliance and damage surrounding objects Do not block the drainage outlet or continuous drainage hose field supplied If using the appliance after ...

Страница 7: ...s and circulate the air around the room If you have an area or location that is specifically in need of dehumidifying place the appliance in the affected area until the humidity is reduced then relocate the dehumidifier to a more central location for best air circulation When placing the dehumidifier ensure it is on a flat and level surface The dehumidifier may vibrate or operate less efficiently ...

Страница 8: ...CATION Control Panel Air Inlet Grille Air filter located behind grille Air Outlet Handle Fig 3 Fig 4 Continuous Drainage Outlet Wheel Electrical Cord Electrical Cord Holder Water Tank Handle Water Tank Full Tank Float ...

Страница 9: ...ehumidifying LED 3 The DEHUMIDIFYING LED indicates when the dehumidifier is functioning and the compressor is running This light goes out when the appliance cycles off when the selected humidity level has been met or the power is off Control Knob 4 The Control Knob 4 is used to select a relative humidity level to set continuous dehumidifying or to turn off the appliance Operating Instructions Note...

Страница 10: ... it is removed and replaced frequently Only remove the water tank when full or when the dehumidifier is off Using Continuous Drainage In situations of extremely high humidity or for convenience you may find connecting continuous drainage more suitable To connect continuous drainage remove the water tank Carefully remove the continuous drainage outlet cover from the rear of the dehumidifier refer t...

Страница 11: ...ses are free of kinks and obstructions Removing and cleaning the filter Remove the water tank Locate the base of the filter and pull vertically down in the direction of the arrow on the filter Fig 8 To clean the filter use a vacuum cleaner or tap the filter lightly to remove dust and dirt If the filter is unable to be cleaned by vacuum use warm water with a small amount of medium strength detergen...

Страница 12: ...hat the dehumidifier is placed on a flat stable and secure surface The dehumidifier is leaking Check that the dehumidifier is in good working order and the cabinet and water tank is not cracked NOTE If problems persist switch off the dehumidifier and unplug from the main power source Contact TECO Australia Service as soon as possible Never attempt to repair the appliance It is hazardous for anyone...

Страница 13: ... Hz 50 Rated Power Input W 355 Rated Run Current A 1 8 Weight Kg 13 3 Rated dehumidifying capacity 12L 24 Hr 30o C DB 80 RH Dimensions mm H 561 W 320 D 276 Operating temperature range 5o C 35o C Water tank capacity L 3 6 Note Data shown in this table is subject to change without prior notice ...

Страница 14: ...www teco com au HBB PV ...