![TECO 7200 MA Series Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/teco/7200-ma-series/7200-ma-series_manual_1072443005.webp)
1-5
(C)
For 220V 15~25HP and 440V 15~30HP Series
■
Removing the digital operator :
Take off the screws in the place a and b.
Disconnect the RS-232 cable connector on the
back side of the LCD digital operator and then lift
the digital operator upwards.
■
Removing the front cover :
Loosen the two screws of the front cover in the
place c and d. And lift the bottom of the front
cover to remove the front cover.
■
Mounting the front cover and digital operator :
Insert the tab of the upper part of front cover into
the groove of the inverter and tighten the screws
in the place c and d.
Connect the RS-232 cable connector on the back
of the LCD digital operator.
Attach the digital operator and tighten the screws
in the place a and b.
Front
Cover
LCD Digital
Operator
a
b
c
d
RS-232 Cable
Connector
(D) For 220V 30~40HP and 440V 40~75HP Series
■
Removing the front cover : Loosen the
two screws of the front cover in the
place a and b. Then loosen the two
screws c and d
,
lift the front cover
upwards. (Don’t removing the digital
operator.)
■
Mounting the front cover: Press the
front cover and then tighten the screws
in the place a, b, c and d.
Front cover