Line Gp front

1. Install the auxiliary valves 555-8147 on the Rh and Lh side of the main control valve, between control valve 

and Cover-Gp-valve-end

2. referring the SIS page 490-2714, connect the harnesses as indicated

WARNING

: harnesses, valves 555-8147 with rods, seals and accessories are not included in the kit

Division: Tecnoter srl 

Hp two ways, two

pumps. Basic ver.

ILBJ

O KEL

CAT 330NG 

Reach – 3,2 mt

Page 11/16

Rev: 1.1_En  –

05/03/2020

Print SIS pages

560-3923
558-8894
490-2714

Содержание ILBJ O Series

Страница 1: ...VERSION SERIES SERIES O O HOST HOST MACHINE MACHINE CAT 330 N CAT 330 NEXT EXT G GEN EN KEL Reach boom 516 8562 Stick 3 2 mt 516 8567 Installation manual Division Tecnoter srl Hp two ways two pumps Ba...

Страница 2: ...revent unauthorized use or distribution of caterpillar manuals and intellectual property rights in accordance with the rules defined with Caterpillar Work Tool inc this manual is printed WITHOUT drawi...

Страница 3: ...of the manual 6 Addressees 6 GENERAL INFORMATION 7 Manufacturer identification 7 INSTALLATION PROCEDURE 8 Line Gp stick line Gp boom 9 Line Gp front 11 Electronic set up 15 CONTACTS 16 Division Tecnot...

Страница 4: ...for this purpose will be rewarded by the correct functioning of the system and by its use in safety conditions This document assumes that the plants where this system will be set comply with the curre...

Страница 5: ...y Logo Product Name Model Serial no Page no Revision no TABLES NUMBERING Every table is numbered progressively Numbering starts from 1 at every section Numbering is composed as follows ABBREVIATIONS S...

Страница 6: ...or changing the old chapters the cover and the table of contents with the new ones in every owned copy Addressees This manual addresses to the operator the assembler and the maintenance technicians OP...

Страница 7: ...la Chiesa 6 20098 San Giuliano Milanese MI Italy After sales service Spare parts Via Carlo Alberto dalla Chiesa 6 20098 San Giuliano Milanese MI Italy CONTACTS Tel 39 029824 8180 9339 9305 Fax 39 0298...

Страница 8: ...e host machine Attention Be sure to have understood the installation manual before the installation of the system Double check each hydraulic installation before operate the system Attention In case o...

Страница 9: ...the hose 253 6558 to the tube just installed 2 Using the provided clamps bolts and washers install the tube 253 6454 with valve 389 2407 on the stick Rh side then connect the hose 253 6562 to the tube...

Страница 10: ...n the Rh side of the boom 6 Connect the hose 356 8077 to the Rh line rear side 7 Using the provided clamps bolts and washers install the Lh line 556 1395 plus 556 1396 on the Lh side of the boom 8 Con...

Страница 11: ...valve end 2 referring the SIS page 490 2714 connect the harnesses as indicated WARNING harnesses valves 555 8147 with rods seals and accessories are not included in the kit Division Tecnoter srl Hp tw...

Страница 12: ...8 5959 left branch 8 Using the hose F12H F40F L4126 A1100 76 548 4580 connect the block BLCK1GC to the upper port of the valve 555 8147 tank side 9 Using the hose F12H F40F L4126 A700 180 548 4583 con...

Страница 13: ...connection BA114330320NG to 442 0234 11 VEI12x160 connection hose 282 5760 to BLCK114GP 12 BTE12X30 with washers WA12 connection SLR330320NG to BLCK114GCFP and 442 0234 13 BTE8X20 with washer WA8 conn...

Страница 14: ...the existing 516 9234 in 516 9236 welding the provided flange block and drilling in correspondence of the flange hole Refer to the page 516 7669 NOTE the threaded boss opposite to the flange has not t...

Страница 15: ...uration before operate the machine and verify that all options are indicated as Not installed Please set up the ECM as follow Machine appl Multiproc Total load pressure sensors 2 Attachment valve 1 an...

Страница 16: ...Eleonora Duse 3 20121 Milan Italy Facility Via Dalla Chiesa 6 20098 San Giuliano Milanese Italy Web www tecnotergroup com email info tecnotergroup com Tech engineering tecnotergroup com Phone 39 0298...

Отзывы: