background image

8.2 ENVIRONMENT PROBE
The plants is regulated on the base of the base of the detected temperature from the external
from the external probe only.
8.2.1 Repeat the steps 8.1.1 e 8.1.2
8.2.2 Press    up to position on         that it will start to flash. The status is OFF.

30

   

 

 

 

 

 

Fig.23

Fig.24

 

Содержание TE035BI

Страница 1: ...WALL MOUNTED TOUCH THERMOSTAT...

Страница 2: ......

Страница 3: ...intuitive graphics interface It s supplied with an in cell touch display with back lighting that it is the most advanced of the wall mounted category The touch display makes it intuitive easy to prog...

Страница 4: ......

Страница 5: ...ual Automatic Energy consumption savings indicator Set temperature Cooling time Heating Temperature Set Reduction temperature ON Set Comfort temperature ON Frost protection OFF Low batteries Note When...

Страница 6: ...ling Set comfort reduction temperature Function Off Lock setting Temperature setting External probe setting Boiler deadlock Reset Supply battery replacement Technical features Safety warnings 5 9 10 1...

Страница 7: ...hook the base from the thermostat Fix the base to the wall Connect the load to the terminals following the wiring diagram Connect the external temperature probe Hook the base to the wall Fit n 2 the b...

Страница 8: ...Pressing the other active keys appear 06...

Страница 9: ...WIRING DIAGRAM 07 NO NO RELAY RELAY...

Страница 10: ...ASSEMBLY 1 Fig 3A Fig 2A Fig 4A Fig 5A Fig 1A Press lift...

Страница 11: ...ng program Reduction temperature Comfort temperature Cooling Program Reduction temperature a 28 C Comfort temperature a 24 C Frost protection 5 C settable active only in heating mode FACTORY SETTING 0...

Страница 12: ...e display by pressing 3 1 2 Press 3 1 3 Press up to position on that it will start to flash 3 1 4 Press OK to confirm The display shows ON and If it s not confirmed after 10 seconds it returns to Stan...

Страница 13: ...10 11 3 2 3 Press up to position on that it will start to flash and OFF appears...

Страница 14: ...12 3 2 4 Press OK to confirm The display shows On and If it s not confirmed after 10 seconds it returns to Stand by SYSTEM ACTIVATION SIGNALING When the icons are animated the system is active...

Страница 15: ...Heating 4 2 Cooling You can set the temperature between 2 and 35 C in steps of 0 1 C by pressing or 4 1 Heating Make sure that the icon is active 4 1 1 Press 4 1 2 Press 4 1 3 Press up to position th...

Страница 16: ...14 4 1 4 Press OK Fig 8 Fig 9 Fig 9...

Страница 17: ...repeat the steps 4 1 1 a 4 1 6 5 1 Press for 4 seconds to switch off thermostat Now the FUNCTION OFF is activated It can be activated with and without Fros Protection It is important to avoid damage c...

Страница 18: ...repeat the steps 4 1 1 a 4 1 6 5 1 Press for 4 seconds to switch off thermostat Now the FUNCTION OFF is activated It can be activated with and without Fros Protection It is important to avoid damage c...

Страница 19: ...5 2 Press for 4 seconds to switch on the thermostat The display shows ON for 3 seconds 17 Fig 10 Fig 11 Fig 12 Fig 12...

Страница 20: ...d accidental changes to the settings caused by unintentionelly touching the screen 6 1 Start display by pressing 6 2 Press and hold simultaneously for 4 seconds and up to position on 6 3 After 3 secon...

Страница 21: ...assword Pressing any key appears Note If you do not confirm with OK key within 15 seconds you return to the previous function without having set the password 6 7 To deactivate it repeat the steps 6 1...

Страница 22: ...s the temperature differential is the difference between this value and the system switch on or switch off temperature For example having set a temperature of 20 C and a differential of 0 3 C the syst...

Страница 23: ...7 1 1 Press 7 1 2 Press 7 1 3 Press up to position on that it will start to flash To set temperature differential 21 Fig 14 Fig 14...

Страница 24: ...ears and flashes ON state appear and flashes ON state appear and indicates that the on off regulation is active 7 1 5 Press OK 7 1 6 press or to set the desired differential value between 0 1 and 1 C...

Страница 25: ...To set it you have to 7 2 1 Repeat the steps 7 1 1 7 1 4 7 2 2 Press and appears and flashes The status is OFF 7 2 3 Press OK to confirm appears and flashes Breath of adjustment range This value can...

Страница 26: ...Press or to set the desired Breadth value 7 2 5 Press OK to confirm tc appears and flashes System Cycle Time It can choose between values 5 10 20 30 40 minutes The factory setting is 20 minutes 24 Fi...

Страница 27: ...e the system power decreases Note For location with good thermal insulation it is advisable to set small band values 7 2 6 Press or to set desired tc value 7 2 7 Press OK to confirm tc stand for the t...

Страница 28: ...s air conditioners the measured current temperature may not be correct For this reason it can correct the measured current temperature by screen from 0 C factory setting to 3 C 7 3 1 Repeat the steps...

Страница 29: ...ures This function works only in the Heating mode The default temperature is 5 C If the temperature drops below this value the system starts working Set the desired temperature within a range from 2 C...

Страница 30: ...28 Fig 20 Fig 21...

Страница 31: ...FF 8 2 ENVIRONMENT PROBE 8 3 EXTERNAL PROBE 8 4 UNDERFLOOR PROBE To set the External Temperature Probe proceed as follows 8 1 EXTERNAL PROBE ON OFF 8 1 1 Press 8 1 2 Press and hold for 3 seconds and a...

Страница 32: ...egulated on the base of the base of the detected temperature from the external from the external probe only 8 2 1 Repeat the steps 8 1 1 e 8 1 2 8 2 2 Press up to position on that it will start to fla...

Страница 33: ...The display shows the temperature measured by the external probe 8 3 EXTERNAL PROBE It only measures another temperature for example the external temperature The system settings do not change 8 3 1 R...

Страница 34: ...From now on the display will a second temperature 8 3 4 To display the temperature of the external probe from standby press then press and ambient temperature appears Press again and appears temperat...

Страница 35: ...off The temperature regulation is managed by the internal probe 8 4 1 Repeat the steps 8 1 1 e 8 1 2 8 4 2 Press up to position on that it will start to flash The status is OFF 8 4 3 Press OK to conf...

Страница 36: ...he floor probe exceeds the set limit temperature the system is switched off Overtemperature protection function The thermoregulation is managed by the internal thermostat probe Note If one of the func...

Страница 37: ...temperature and the display one If after 2 hours the displayed temperature has not changed variation of 0 5 C the programmable thermmostat signals the failure of the system e appear and flash When th...

Страница 38: ...settings also deleting any password 10 1 From stand by press 10 2 Press and hold simultaneously and for 4 seconds appears At this point the device start with all factory settings NB In the event of ma...

Страница 39: ...the replacement of Alkaline style batteries at the brginning of each season Fitting the batteries with the wrong polarity may damage the programmable thermostat The correct date and time settings are...

Страница 40: ...dth of adjustment range from 0 5 C to 7 C of resolution System Cycle Time 5 10 20 30 40 minutes Thermal Differential ON OFF from 0 1 to 1 C Functions Password block Anti seize Pump Boiler Deadlock tak...

Страница 41: ...wheelie bin WEEE symbol on the appliance show that the product at the end of its useful life must be collected separately from other waste Therefore the user must provide the equipment with the essent...

Страница 42: ......

Страница 43: ......

Страница 44: ......

Страница 45: ......

Отзывы: