E
n
g
li
sh
10
blast chiller istrUction c-2003
06/2011
5.9
AUTOMATIC DEFROST CYCLES
(not available for MOD.
q
)
•
the appliance automatically performs defrost cycles during
storage. three defrost cycles are performed during a 24-hour
period(once every 8 hours).
•
the appliance automatically restarts once the defrost cycle
has been completed.
5.10 UV-C LAMP FUNCTION
•
Use this function to sterilize the interior of the cell.
•
when the appliance is
ON
q
, press push-button
s
(relative
leD illuminates). the UV-c lamp switches on and sterilizes
the interior for a default time of 30 minutes. to interrupt the
sterilization cycle, press push-button
s
or open the cell
door. when the door is closed again, the lamp will remain off.
5.11 USER ENTRY TO PROGRAMMING DATA
•
access for programming configuration parameters is only
permitted when the appliance is
ON
q
and there is
no data
memory error
active.
•
Press and hold down push-buttons
u
and
i
at the same
time for more than five seconds; the computer will give ac-
cess to the programming function. Display
j
displays Pa,
while display
h
will show the relative value.
•
Use push-button
t
to select parameter display (leD
t
a il-
luminated), or display 16 with settings (leD
t
illuminated).
•
Use push-buttons
u
and
i
to scroll the list of parameters
(if leD
t
a is illuminated) or to modify the settings (if leD
t
b is illuminated).
•
the computer automatically exits the programming function
after approximately 40’.
5.11.1
User parameter settings
Parameter
Min.
Max.
Unit/meas.
DEF
Pa
PassworD
-99
+99
number
-19
/ = PROBE PARAMETERS
/1
cell probe calibration
-10
+10
°c
0
/2
evaporate probe calibration
-10
+10
°c
0
/3
core probe calibration
-10
+10
°c
0
/8
temperature scale (0=fahrenheit 1=celsius)
0
1
flag
1
c = CHILLING / FREEZING
c0
cell probe differential
1
15
°c
+3
c1
Duration of timed chilling and max. duration for chilling by temperature
0
400
min
90
c2
chilling end set point (core probe)
-55
+99
°c
3
c3
Positive storage set point (cell probe)
-55
+99
°c
2
c4
Duration of timed freezing and max. duration of freezing by temperature
(when c4=0, key and freezing function to -18°c are disabled.
for chilling units only.)
0
400
min
240
c5
freezing end set point (core probe)
-55
+99
°c
-18
c6
negative storage set point (cell probe)
-55
+99
°c
-25
c8
Positive and negative chilling duration countdown start temperature
-55
+99
°c
+65
ca core probe readout (readout only)
---
---
°c
---
cb
set point for soft blast chilling (cell probe) and during second stage
of harD blast chilling
-55
+99
°c
-5
cd
ha rD chilling set point (temperature transition harD ->soft of core probe)
-55
+99
°c 2
0
cf
cell set point during first stage of harD blast chilling (core probe)
-55
+99
°c
-20
d = DEFROST
d0 Defrosting interval (0 = no defrost)
0
99
hours
8 h
da Defrost probe readout (readout only)
---
---
°c
---
U = VARIOUS
u5 Duration of UV lamp activation (if u5=0, UV key is disabled)
0
99
min
0
ua Print interval (when ua=0, haccP key is disabled)
0
99
min
20