E
n
g
li
sh
9
blast chiller istrUction c-2003
06/2011
5. APPLIANCE FUNCTIONS
5.1
DATE AND TIME SETTINGS
t
•
set the machine to
ON
q
.
•
Press and hold down push-button 5
t
for more than five
seconds to access the date and time setting function. Display
j
indicates in sequence the abbreviations hr (hours), mn
(minutes), da (day), mo (month) and yr (year), while display
h
shows their respective settings. to scroll the abbrevia-
tions, press push-button 5
t
.
•
to modify the settings, use push-buttons
u
and
i
.
5.2
ICE CREAM SURFACE HARDENING
y
•
set the machine to
ON
q
.
•
Press and hold down push-button
y
for more than five se-
conds to access the surface hardening function (push-button
leD flashes). the compressor is switched on; display
h
shows the default cycle time. set the cycle time (in minutes)
by means of push-buttons
u
and
i
.
•
open the cell door, place the product inside, then shut the
door to start the cycle. all leDs remain off, with the exception
of the start leD. when the cycle time has elapsed, an acou-
stic signal is given. the appliance remains on, ready for ano-
ther ice cream hardening cycle. open the cell door, remove
the hardened product, replace it, then shut the door. the ma-
chine will perform another hardening cycle for the time set
for the previous one. every time the door is opened and clo-
sed after a cycle, the time is reset.
•
to exit the function, press push-button 6
y
.
ADDITIONAL FUNCTIONS
5.3
MUTING THE BEEPER AND ALARM RESET
i
•
Press push-button
i
to mute the alarm beeper.
•
alarms are reset :
- by pressing push-button
i
when the beeper is off;
- automatically if alarm conditions are removed;
•
see also section 6 (alarm management).
5.4
PROGRAM STORAGE
o
•
the programming function is used for cycles for processing
products with the same characteristics. Up to 99 programs
can be stored. select the type of chilling process (soft, hard,
timed freezing or by temperature), then press and hold
push-button
o
until display
j
shows the abbreviation P1
(push-button
o
leD flashes).
•
Use push-buttons
u
and
i
to set the number of the pro-
gram on display
j
.
•
start up the cycle by pressing push-button
y
.
•
when the cycle has been completed, the appliance auto-
matically switches to the set storage temperature for an in-
definite time.
•
Press push-button
y
to set the appliance to stoP status (re-
lative leD switches off ), ready for a new cycle.
RECALLING A STORED PROGRAM
•
when the appliance is
ON
q
, press push-button
o
briefly;
display
j
will show program P1. Use push-buttons
u
and
i
to select the required program. start up the cycle by pres-
sing push-button
y
.
5.5
DISPLAYING THE THREE LATEST HACCP ALARMS
a
•
set the machine to
ON
q
.
•
Press and hold down push-button
a
for more than five se-
conds (relative leD illuminates) to enter the alarm display
function (date, hour and minute, alarm type and maximum
temperature detected).
•
every time the haccP push-button is pressed, the stored
data are displayed.
EXAMPLE:
ALL 11
Display
h
Display
j
---
str (start)
12
hr hour
29
min minutes
6
day days
8
mon month
03
yr year
end
end
13
hr
21
min
6
day
8
mon
03
yr
24
maximum temperature
detected inside the cell
5.6
PRINTING OUT STORED DATA
a
•
with the appliance in
STAND-BY
status, press and hold down
push-button
a
for more than five seconds to print out the
latest work cycle.
•
with the appliance in
STAND-BY
status, press push-button
a
once to print out haccP data). when the appliance is
operating and the printer is on, the current cycle will be prin-
ted out.
5.7
FORCED VENTILATION FUNCTION
•
to activate this function when the appliance is
ON
q
, press
push-button
d
for more than five seconds. the fan will con-
tinue to operate even when the cell door is open.
•
During forced ventilation, display
j
will show
“AIR”
.
5.8
MANUAL DEFROSTING
•
to activate this function when the appliance is
ON
q
press
push-button
d
(relative leD illuminates).
•
if conditions allow it (the temperature detected by the eva-
porator probe must be lower than the set point in the pro-
gram parameters), the appliance will perform a defrost cycle.
Display
j
will show
“dEF”
.
•
to immediately stop a defrost cycle, press push-button
d
.