![Tecnoma ECO Скачать руководство пользователя страница 93](http://html.mh-extra.com/html/tecnoma/eco/eco_operating-instructions-manual_1071988093.webp)
Alarm messages
93
990267EN ind. A
Text of alarm message
Meaning
TRAIL Control
The gyroscope is not correctly
mounted
Valid voltage range during calibration: 1.5V to 3.5V
TRAIL Control
Drawbar poti is reversed
The wrong direction of rotation was detected during calibration of the end
stops.
TRAIL Control
Sensors are disturbed
Short signal interruptions with all sensors
Alarm messages connected with spray functions
Text of alarm message
Meaning
Low tank content
The volume of spray mixture in the tank has fallen below the "Tank level alarm"
value.
SPRAY REGULATION
Set value out of reach
The system cannot adjust the application rate to the rate.
SPRAYER
Pump speed too low
The spray liquid pump's speed could be not achieved.
SPRAYER
Pump speed too high
The spray liquid pump's maximum speed was exceeded.
SPRAY REGULATION
The pressure is too low
The minimum spray pressure could not be achieved.
SPRAY REGULATION
The pressure is too high
The maximum spray pressure was exceeded.
The wind is too strong
The wind is stronger than the maximum wind strength.
Alarm messages connected with the boom
Text of alarm message
Meaning
Boom out of transport position
Maximum speed of the field sprayer was exceeded.
Defective potentiometer
Alarm when height control is configured but the potentiometer is recognized as
faulty.