FOREWORD
This manual contains the information
necessary for the product to be installed
correctly and also instructions for its
maintenance and use; we therefore recommend
that the utmost attention is paid to the following
instructions and to save it.
This document is the exclusive property of TECNOLOGIC
S.p.A. which forbids any reproduction and divulgation , even
in part, of the document, unless expressly authorized.
TECNOLOGIC S.p.A. reserves the right to make any formal or
functional changes at any moment and without any notice.
Whenever a failure or a malfunction of the device may cause
dangerous situations for persons, thing or animals, please
remember that the plant has to be equipped with additional
devices which will guarantee safety.
Tecnologic S.p.A. and its legal representatives do not assume
any responsibility for any damage to people, things or animals
deriving from violation, wrong or improper use or in any case
not in compliance with the instrument’s features.
INDEX
INSTRUMENT ORDERING CODE
7.5
FUNCTIONAL DATA
7.4
MECHANICAL DIMENSIONS AND MOUNTING
7.3
MECHANICAL DATA
7.2
ELECTRICAL DATA
7.1
TECHNICAL DATA
7
GUARANTEE AND REPAIRS
6.3
CLEANING
6.2
SIGNALLING
6.1
PROBLEMS , MAINTENANCE AND GUARANTEE
6
PROGRAMMABLE PARAMETERS TABLE
5
FUNCTION OF KEYS “U” AND “DOWN/AUX”
4.11
OPEN DOOR ALARM
4.10.3
EXTERNAL ALARM (DIGITAL INPUT)
4.10.2
TEMPERATURE ALARMS
4.10.1
ALARM FUNCTIONS
4.10
EVAPORATOR FANS CONTROL
4.9
DEFROST DISPLAY LOCK
4.8.4
END DEFROST
4.8.3
MANUAL DEFROST
4.8.2
AUTOMATIC DEFROST STARTS
4.8.1
DEFROST CONTROL
4.8
COMPRESSOR PROTECTION FUNCTION AND DELAY
AT POWER-ON
4.7
TEMPERATURE CONTROL
4.6
ACTIVE SET POINT SELECTION
4.5
OUTPUTS AND BUZZER CONFIGURATION
4.4
DIGITAL INPUT
4.3
MEASURING AND VISUALIZATION
4.2
ON / STAND-BY FUNCTION
4.1
FUNCTIONS
4
ELECTRICAL WIRING DIAGRAM
3.4
ELECTRICAL CONNECTIONS
3.3
MECHANICAL MOUNTING
3.2
PERMITTED USE
3.1
INFORMATION ON INSTALLATION AND USE
3
KEYBOARD LOCK FUNCTION
2.7
PARAMETERS CONFIGURATION BY “A01”
2.6
RESET PARAMETERS TO DEFAULT VALUE/LEVEL
2.5
CUSTOMIZED MODE PARAMETER PROGRAMMING
(PARAMETERS PROGRAMMING LEVEL)
2.4
PARAMETER PROTECTION USING THE PASSWORD
2.3
STANDARD MODE PARAMETERS PROGRAMMING
2.2
FAST PROGRAMMING OF SET POINT
2.1
PROGRAMMING
2
FRONT PANEL DESCRIPTION
1.2
GENERAL DESCRIPTION
1.1
INSTRUMENT DESCRIPTION
1
1 - INSTRUMENT DESCRIPTION
1.1 - GENERAL DESCRIPTION
The model W09Y is a digital controller with microprocessor that is
typically used in cooling applications that have temperature control
with ON/OFF regulation and defrosting control at intervals time or
at reaching temperature by stopping compressor or by means of
electrical heating or hot gas/reverse cycle.
The instrument has up to 3 relay outputs, up to 3 inputs for PTC or
NTC temperature probes and a digital input (aternative to an
temperature input), in addition can be equipped with an internal
buzzer that is the sound system for alarms.
The 3 outputs can be can all be configured for controlling the
compressor or the temperature control device, the defrosting
device, the evaporation fan or, alternatively any of the previous
functions, using an auxiliary device or an alarm.
The 3 inputs for temperature probes can be used to measure the
control temperature, the evaporator temperature, products or aux
temperature, while the digital input alternative to evaporator or aux
temperature input can be programmed to carry out various
functions such as door opened signal, defrosting commands,
selecting a different set of temperature regulations, external alarm
TECNOLOGIC spa - W09Y
- OPERATING INSTRUCTIONS - Vr. 01 - 07/09 - ISTR-MW09YENG1 - PAG. 1