7.4 - FUNCTIONAL FEATURES

Temperature Control: ON/OFF mode

Measurement range: Pt1000 : -100 ... 500 °C (-99,9 ... 500,0 °C) /
-148 ... 932 °F (-99,9 ... 932,0 °C); NTC (PT-24C2)  : 0...300 °C / 32

...572 °F
Display resolution: 1 ° or 0,1°

Overall accuracy: Pt1000 : +/- (0,5 % fs + 1 digit); NTC (PT-24C2)  
: +/- (1 % fs + 1 digit)

Sampling rate: 130 ms.
Display: 4 Digit  Red h 12 mm

Compliance: ECC directive EMC 89/336 (EN 61326), ECC directive
LV 73/23 and 93/68 (EN 61010-1)

7.5 - INSTRUMENT ORDERING CODE

TLZ 11  a b c d ee P

a : POWER SUPPLY
H

 = 100...240 VAC

L

 = 24 VAC/VDC

F

 = 12 VAC/VDC 

b : OUTPUT OUT TYPE
S

 = Relay SPDT 16A-AC1

R

 = Relay SPST-NO 16A-AC1

c : ALARM OUTPUT

= Relay

-

 = None

d : INTERNAL BUZZER
B

 = Yes

-

 = No

ee : SPECIAL CODES

TECNOLOGIC spa - TLZ 11

 

P

 

- OPERATING INSTRUCTIONS - Vr.01  - 09/05 - ISTR 06947 - PAG. 6

Содержание TLZ 11 P

Страница 1: ...UNCTION OF KEY U 4 6 DIGITAL INPUT 4 5 EXTERNAL ALARM 4 4 2 TEMPERATURE ALARMS 4 4 1 ALARM FUNCTIONS 4 4 COMPRESSOR PROTECTION FUNCTION AND DELAY AT POWER ON 4 3 TEMPERATURE CONTROL 4 2 MEASURING AND VISUALIZATION 4 1 FUNCTIONS 4 ELECTRICAL WIRING DIAGRAM 3 4 ELECTRICAL CONNECTIONS 3 3 MECHANICAL MOUNTING 3 2 PERMITTED USE 3 1 INFORMATION ON INSTALLATION AND USE 3 ON STAND BY FUNCTION 2 5 PARAMETE...

Страница 2: ...first parameter and it will be possible to set the parameters of the instrument using the same programming procedure described previously Once the parameter has been selected and the SET is on it means that the parameter can be programmed even on the first level visible If the LED is off it means that the parameter can only be programmed on this level i e hidden To change the visibility of the par...

Страница 3: ... mode programmed on the parameter Func the differential is automatically considered by the regulator with positive values for a Refrigeration control Func CooL or with negative values for a heating control Func HEAt In the event of probe error it is possible to set the instrument so that that the output OUT continues to work in cycles according to the times programmed in the parameter tonE activat...

Страница 4: ... as diF 3 see par 4 5 At the same time as the signalling of the alarm buzzer and or output the instrument signals the alarm by turning on the led AL and visualising AL and the measured temperature alternately on the display 4 5 DIGITAL INPUT The digital input present on the instrument accepts contacts free of voltage the function carried out is defined by the parameter diF The parameter diF can be...

Страница 5: ... is limited to repairs or to the replacement of the instrument The eventual opening of the housing the violation of the instrument or the improper use and installation of the product will bring about the immediate withdrawal of the warranty s effects In the event of a faulty instrument either within the period of warranty or further to its expiry please contact our sales department to obtain autho...

Страница 6: ...racy Pt1000 0 5 fs 1 digit NTC PT 24C2 1 fs 1 digit Sampling rate 130 ms Display 4 Digit Red h 12 mm Compliance ECC directive EMC 89 336 EN 61326 ECC directive LV 73 23 and 93 68 EN 61010 1 7 5 INSTRUMENT ORDERING CODE TLZ 11 a b c d ee P a POWER SUPPLY H 100 240 VAC L 24 VAC VDC F 12 VAC VDC b OUTPUT OUT TYPE S Relay SPDT 16A AC1 R Relay SPST NO 16A AC1 c ALARM OUTPUT R Relay None d INTERNAL BUZZ...

Отзывы: