- 17 -
INSTALLATION
Electrical connection
WARNING: THIS APPLIANCE MUST BE EARTHED.
This appliance should be wired into a 16 A double pole switched fused spur
outlet, having 3 mm contact separation and placed in an easily accessible
position adjacent to the appliance. The spur outlet must still be accessible
even when your oven is located in its housing to enable the appliance to be
disconnected from the mains supply.
To connect the oven power cord, loosen and remove the cover on the
terminal block, in order to gain access to the contacts inside. Make the
connection, securing the cord in place with the cable clamp provided and
then immediately close the terminal block cover again.
If you have to change the oven power cord, the earthing (yellow/green)
conductor must always be 10 mm longer than the line conductors.
Care must be taken to ensure that the temperature of the mains supply cable
does not exceed 50°C.
If the mains supply cable is damaged, then it must be replaced by an
appropriate replacement which can be obtained from Spares Department.