_ Electric Cookers _ rev. 1 _________________________________________________________ KCV 96 P – KCV 96_
_ CATEGORY II2H3+ _ GB __
0705
_____________________________________________________ page 11 _
The power cable must comply with the following characteristics:
KCV 96 P
KCV 96 P
KCV 96 P
KCV 96 P
KCV 96
KCV 96
KCV 96
KCV 96
Power supply voltage
Power supply voltage
Power supply voltage
Power supply voltage (V~)
(V~)
(V~)
(V~)
220 – 230
380 – 400 2N
Power cable diameter
Power cable diameter
Power cable diameter
Power cable diameter
3x1.5 mm
2
4x2.5 mm
2
Type of power cable
Type of power cable
Type of power cable
Type of power cable
H07RN-F
Safety device
Safety device
Safety device
Safety device - The appliance is supplied with a manually resetting thermal breaker to protect
against excessive, dangerous temperatures which could be accidentally generated inside the
oven. If tripped, the device cuts out electrical power to the appliance. To access this device,
remove the panel at the rear of the appliance.
6.
6.
6.
6. Adapting cook
Adapting cook
Adapting cook
Adapting cook----top
top
top
top to different types of gas
to different types of gas
to different types of gas
to different types of gas
To adapt the hob to a type of gas that differs
from the one tested in the factory (see data plate
or supplementary plate), replace the nozzles of
the five burners Remove the pan carrier grilles
from the hob and withdraw the movable parts of
the burners from their seats:
-
Remove the pot support grids from the
cook-top and remove the mobile parts of
the burners from their position.
-
Unscrew the jets (Fig. 2) using the 7 mm.
Key and replace them with the new ones
(see
table
1).
Check
the
exact
correspondence of the diameter indicated
on the table with that printed on the jets.
After having replaced the jets, set up all the
parts again and stick the new data on the
technical data plate.
Fig.
Fig.
Fig.
Fig. 2
2
2
2
N.B.
N.B.
N.B.
N.B. The burners don’t need any air regul
The burners don’t need any air regul
The burners don’t need any air regul
The burners don’t need any air regulation
ation
ation
ation....
Minimum level adjustment
Minimum level adjustment
Minimum level adjustment
Minimum level adjustment - Burner minimum levels are preset for methane gas (G20)
operation. If operating on liquid gas (G30/G31) proceed as follows: ignite the burner at
minimum position, and, using a screwdriver, fully tighten the by-pass adjustment screw at the
side of the shank of the relevant tap. Check if the flame remains stable and uniform – to help
you check, rapidly turn the tap knob from maximum to minimum position. When you have
finished adjusting the by-pass valve, seal it with red paint. Make sure you fit a plate with the
new installation data. After having set the by-pass screw, seal it with red varnish.
Gas pressure (mbar)
Gas pressure (mbar)
Gas pressure (mbar)
Gas pressure (mbar)
Type of gas
Type of gas
Type of gas
Type of gas
Normal
Normal
Normal
Normal
Max.
Max.
Max.
Max.
Min.
Min.
Min.
Min.
Table 1
Table 1
Table 1
Table 1
G30
G30
G30
G30
30
30
30
30
35
35
35
35
20
20
20
20
G31
G31
G31
G31
37
37
37
37
45
45
45
45
25
25
25
25
G20
G20
G20
G20
20
20
20
20
25
25
25
25
17
17
17
17
Main nozzles diameter
Main nozzles diameter
Main nozzles diameter
Main nozzles diameter
(1/100 mm)
(1/100 mm)
(1/100 mm)
(1/100 mm)
By
By
By
By----pass screw nozzles
pass screw nozzles
pass screw nozzles
pass screw nozzles
diameter
diameter
diameter
diameter
(1/100 mm)
(1/100 mm)
(1/100 mm)
(1/100 mm)
Consumption calculated with gross
Consumption calculated with gross
Consumption calculated with gross
Consumption calculated with gross
heat values
heat values
heat values
heat values
Nominal
Nominal
Nominal
Nominal
thermal
thermal
thermal
thermal
capacity
capacity
capacity
capacity
(kW)
(kW)
(kW)
(kW)
Reduced
Reduced
Reduced
Reduced
thermal
thermal
thermal
thermal
capacity
capacity
capacity
capacity
(kW)
(kW)
(kW)
(kW)
G30/G31
G30/G31
G30/G31
G30/G31
30/37mbar
30/37mbar
30/37mbar
30/37mbar
G20
G20
G20
G20
20mbar
20mbar
20mbar
20mbar
G30/G31
G30/G31
G30/G31
G30/G31
30/37mbar
30/37mbar
30/37mbar
30/37mbar
G20
G20
G20
G20
20mbar
20mbar
20mbar
20mbar
G30
G30
G30
G30
30mbar
30mbar
30mbar
30mbar
(g/h)
(g/h)
(g/h)
(g/h)
G31
G31
G31
G31
37mbar
37mbar
37mbar
37mbar
(g/h)
(g/h)
(g/h)
(g/h)
G20
G20
G20
G20
20mbar
20mbar
20mbar
20mbar
(l/h)
(l/h)
(l/h)
(l/h)
Triple crown
Triple crown
Triple crown
Triple crown
burner Nr.
burner Nr.
burner Nr.
burner Nr. 1
1
1
1
3.
3.
3.
3.5
5
5
5
1.
1.
1.
1.8
8
8
8
95
95
95
95
135
135
135
135
74
74
74
74
Regul.
Regul.
Regul.
Regul.
255
255
255
255
250
250
250
250
334
334
334
334
Fast
Fast
Fast
Fast burner
burner
burner
burner
Nr.
Nr.
Nr.
Nr. 3
3
3
3
3
3
3
3
0.
0.
0.
0.95
95
95
95
85
85
85
85
115
115
115
115
50
50
50
50
Regul.
Regul.
Regul.
Regul.
218
218
218
218
214
214
214
214
286
286
286
286
Semi
Semi
Semi
Semi----fast
fast
fast
fast burner
burner
burner
burner
Nr. 1
Nr. 1
Nr. 1
Nr. 1
1.
1.
1.
1.75
75
75
75
0
0
0
0....6
6
6
6
65
65
65
65
97
97
97
97
40
40
40
40
Regul.
Regul.
Regul.
Regul.
127
127
127
127
125
125
125
125
167
167
167
167