finished adjusting the by-pass valve, seal it with red paint. Make sure you fit a plate with the
new installation data. After having set the by-pass screw, seal it with red varnish.
Gas pressure (mbar)
Type of gas
Normal
Max.
Min.
Table 2
G30 30
35
20
G31 37
45
25
G20 20
25
17
Main nozzles diameter
(1/100 mm)
By-pass screw nozzles
diameter
(1/100 mm
)
H distance for air
adjustment
(mm)
Consumption calculated with
gross heat values
Nominal
thermal
capacity
(kW)
Reduced
thermal
capacity
(kW)
G30/G31
30/37mbar
G20
20mbar
G30/G31
30/37mbar
G20
20mbar
G30/G31
30/37mbar
G20
20mbar
G30
30mbar
(g/h)
G31
37mbar
(g/h)
G20
20mbar
(l/h)
Triple crown
burner Nr. 1
3.6 1.8 90 140 74 Regul. 6 6 262
257
343
Fast burner
Nr. 3
3.1
0.95 83 130 50 Regul. 6 4 226
222
296
Semi-fast
burner Nr. 1
2.7 0.6 77 119 40 Regul. 6 4 197
193
257