1.5 INSTALLATION INSIDE YOUR SHOP/RESTAURANT/WORKROOM
The equipments are tested in test-room with ambient temperature of +25°C and relative humidity
60%
, therefore, if the ambient in which the equipment is installed has different conditions of ambient temperature
and relative humidity, it could be veri
fi
ed a malfunction and the equipment will not run properly (making inside
condensation….etc). It is advisable to install the equipment inside an area with an air conditioning system. Please
note that malfunctions may arise in areas that are not provided with air conditioning, e.g. condensation formation.
ATTENTION
In order to allow a good functioning of the
equipment please pay attentions to the following instructions:
•
Do not place the unit in an area directly exposed to sun light or to other heating sources,
such as high
intensity incandescent lighting systems, ovens or other radiant heating sources, e.g. heating radiators etc.
•
Do not place the unit nearby door openings producing air currents,
whether doors or windows
or directly exposed to air from fans, vents or fan coil unit air conditioner.
•
Do not block or obstruct the air inlets
of the built-in refrigeration unit
.
•
Do not place any objects on the unit,
including boxes or any other type of objects; leave the entire
perimeter of the unit completely free so that air can circulate properly
.
•
Do not place the equipment inside areas with high relative humidity levels
(it may cause formation of condensation)
•
Do not place the equipment inside a closed niche,
as there is not enough air circulation and may
cause the refrigeration unit to not work properly.
•
Do not place the unit one above another.
•
Verify that the room in which the equipment is placed must be suf
fi
ciently aired,
even when the shop is closed.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
INSTALLATION
MINIMUM
DISTANCE
In order to allow a good
performance of the ca-
binet, during the instal-
lation you must respect
the MINIMUM WALL
distances as showed on
the drawings.
1.6 WATER CONDENSATION DRAIN / WATER DRAIN CONNECTION
The Vertical Multi-deck Display with built-in unit is
fi
tted with automatic evaporating water con-
densation tank with stainless steel cooling
(tank not removable).
Veri
fi
ed that the water pipe is
correct positioned
and periodically and the basin is must be cleaned from waste materials.
The Vertical Multi-deck Display with remote unit
, not having the basin for water collection is provided with
a siphon only, the customer take care of the water connection pipe. Its connection to the principal basin prevents
the circulation of cold air and of bad smells.
The Vertical Multi-deck Display cannot absolutely be installed
without siphon and each drain must have its own siphon
. It is necessary to have the drain-siphon after the
exit of belly section to block the out-take air and also to avoid any smell. You never install the equipment without
siphon and to connect more drains of the same equipment together.
Each drain must have only one siphon.