background image

TFNET

19

Con

fi

 guration repeaters

28/10/2016

28/10/2016

28/10/2016

28/10/2016

Menu Confi guration repeaters

Repeater 1
Repeater 2
Repeater 3
Repeater 4
Repeater 5
Repeater 6
Repeater 7
Repeater 8
Repeater 9
Repeater 10

Menu software options

Enabling 1
Enabling 2
Enabling 3
Enabling 4
Enabling 5
Enabling 6
Enabling 7
Enabling 8
Send
Reception

Menu software options: Enabling 5

00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000

Menu Confi guration repeater 1

Enabling
Description
Voice msg
Type
Software options

Enabled

TFNET

00000000

Enabled

Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled

Access level 3

Access level 3

Access level 3

Access level 3

08:18:59

08:18:59

08:18:59

08:18:59

Software licenses that allow to extend the capabilities of the device TFNET can be purchased at any time. At the time of purchase 
a code is issued that must be entered in the con

fi

 guration menu of the repeater. When a valid code is recognized, the device 

enables the related functions.

8 - SOFTWARE OPTIONS

00000000

5 MODBUS

3 TECNO OUT

TFNET - Software options

Option

Description

Name

Item no.

3

TECNO OUT protocol management

TFABIL-TECNO

TF2TFABILTECNO

5

MODBUS protocol management

TFABIL-MODBUS

TFTFABILMODBUS

Note:

 The option numbers not mentioned have not yet been assigned

Enabling of software options

Enabling of software options can only be performed from 
the control panel setting menu "Repeaters".

Select and access the menu, select the address of 
the repeater on which you want to assign the software 
option.
Access the setting menu of the Repeater.

Select "Software options" and access the menu.

Select a row. e.g. select option 1 and access its entry form.

Enter the alphanumeric enabling code and exit the menu.

Send the enabling code to the device.
Select the item Send and con

fi

 rm with the OK key.

Receive from device the status of its software options.
Select the item Receive and con

fi

 rm with the OK key.

Check the mask of the software options of the device and 
exit setup

00010000

5 MODBUS

3

Sosftware options

The enabling code consists of 8 numbers (either 0 or 1).
Number 0 indicates that the corresponding option is not active on the device, number 1 indicates that the corresponding option 
is active on the device.
In the opposite example the only active option is number 5.

Select the software 

options menu

Select the address 

of the repeater 

Access the repeater

Access the menu

Select the number of 

the software option

Select Receive 

and con

fi

 rm 

with the OK key

Select the character

Enter the character

Delete the last 

character

At entry end

Select Send 

and con

fi

 rm 

with the OK key

Access enabling code 

entry form

Access the menu

Содержание TecnoFire TFNET

Страница 1: ...by Installation Document version 0 3 FW version 1 0 00 HW version TFNET Setup SW version 5 2 Update date 12 2016 Language English TFNET Communication interface...

Страница 2: ...TFNET 2 TFNET TFAXFIRE Systems Compatibility TFA1 298 Ver 1 3 09 TFA2 596 Ver 1 3 09 TFA4 1192 Ver 1 3 09...

Страница 3: ...4 INSTALLATION NOTES 4 1 Assembly view 11 4 2 Installation 12 4 3 Connection cables 12 5 USER INTERFACE 5 1 Front panel 13 5 2 LED 13 6 OPERATING MODES OF THE SYSTEM 6 1 Access levels and codes 15 6 2...

Страница 4: ...TFNET 4...

Страница 5: ...horough knowledge of the product acquired attending specific training courses at the premises of Tecnofire fire systems division of Tecnoalarm S r l Environmental requirements The TFNET communication...

Страница 6: ...TFNET 6...

Страница 7: ...gnificant checks should include at least Functional state of power supply units and accumulators APS of the control panel and of the system power supply modules State of the batteries of the self powe...

Страница 8: ...TFNET 8...

Страница 9: ...1999 05 EC class 1 TTE Standards EN 50136 1 1 EN 50136 2 1 Approved for use with TFA1 298 TFA2 596 and TFA4 1192 control panels General speci cations Model TFNET Description Ethernet interface Protoco...

Страница 10: ...TFNET 10...

Страница 11: ...tor 4 INSTALLATION NOTES Introduction In Italy the installation of this device is regulated by UNI and national standards including DM 37 of 22 Jan 2008 which requires that fire protection systems are...

Страница 12: ...ation interface is an expansion device for the TFAXFIRE control panels and is connected to them via the Master and or Slave RS485 BUSES The BUS can be connected in open loop or closed loop mode In the...

Страница 13: ...pply status of the device Off Power supply off On Power supply on Green Indicates the status of the connections of the channels SERVER 1 SERVER 2 TECNOALARM TECNOSERVER TECNOALARM SERVICE Off No commu...

Страница 14: ...TFNET 14...

Страница 15: ...sing the RESET key B Switch the unit operating state manned to Unmanned and vice versa C Manually activate an Evacuation alarm D Access the list of menus reserved to Level 2 Level 3 It is possible to...

Страница 16: ...is the selection pointer The pointer can be moved using the arrow keys up or down The choice of the menus can also be done by entering the quick selection number 6 2 Access level 2 The control panel...

Страница 17: ...he device is the last device connected on the Bus Of course only if the connection Bus is in open line configuration Identification Normal condition Function JP1 RESET Open Hardware reset JP2 BOOT Ope...

Страница 18: ...TFNET 18...

Страница 19: ...TFABILMODBUS Note The option numbers not mentioned have not yet been assigned Enabling of software options Enabling of software options can only be performed from the control panel setting menu Repeat...

Страница 20: ...TFNET 20...

Страница 21: ...ce in the network is identified with the same address of the TFNET 192 168 0 10 Attention before proceeding please be sure to have the file required for the update The file is available from the site...

Страница 22: ...change Type Size Open Cancel Exit Reading OK Find device on IP 192 168 0 10 port 10001 Tecnoboot status requested Status BOOT_READY Type PROG GSM Version 0 4 Block dim 1024 mult 4 Address 8010000 808...

Страница 23: ...TFNET 23 NOTES...

Страница 24: ...842 Via Ciri 38 10099 San Mauro T se Torino Italy Production Unit Strada del Cascinotto 139 54 10156 Torino Italy Tel 39 011 22 35 410 Fax 39 011 27 35 590 info tecno redetection com www tecno redetec...

Отзывы: