1. SAFETY PRECAUTIONS 

1. Before to start using the FGM Charger, read these instructions carefully. 

2. Installation and Service operations can be done by qualified personnel only. 

3. To prevent the risk of electric shock, don’t touch uninsulated parts of the charger or the battery. 

4. Manually stop the charger before to disconnect the battery. 

5. The charger is suitable for indoor installation, in ambient with abundant ventilation. 

6. Don’t use the charger near flammable materials. 

7. Don’t obstruct the ventilation slots and leave sufficient free space around the unit. 

8. Don’t expose the charger to liquids, excessive dust or vibration. 

9. Check the conditions of cables and accessories on a regular basis, and replace them immediately 
if they get damaged. 

10. Don’t extend the batter cables. Replace them, if necessary, with cables of the same type, 
length, section and insulation as the original ones. 

11. During the installation of the charger, make sure to connect the EARTH conductor properly, 
and respect all the applicable Safety Standards. 

12. Don’t modify any part of the charger. Any modification, applied without written authorization 
of the manufacturer, may generate unsafe operating conditions and will void the warranty. 

 

2. Description 

The FGM Charger has been designed to charge Lead-Acid or GEL motive batteries. This charger 
converts the AC input to DC, at the proper value to charge the battery 

The FGM is based on High-Frequency Switchmode technology, which allows very compact size and 
efficient operation. The operation is completely automatic, and it’s managed by a microprocessor 
based control system. 

The exclusive charging curve of the FGM charger allows to reduce the charging factor to the 
minimum value, so the duration of the overcharge/gassing phase and the average temperature of 
the battery are minimized. 

 

3. INSTALLATION 

Conditions of use: 

-

 

Temperature (operation):                       from 0°C t 40°C 

-

 

Temperature (storage):                           from -20°C to 60°C 

-

 

Relative Humidity:                                    less than 75% 

 

Содержание PRATIK PHF812-FGM

Страница 1: ... VMTL006 2016 03 PRATIK PHF812 FGM USER S MANUAL www Tecnikchargers com ...

Страница 2: ...as the original ones 11 During the installation of the charger make sure to connect the EARTH conductor properly and respect all the applicable Safety Standards 12 Don t modify any part of the charger Any modification applied without written authorization of the manufacturer may generate unsafe operating conditions and will void the warranty 2 Description The FGM Charger has been designed to charg...

Страница 3: ...ed and it opens if the battery voltage is lower than a programmed minimum value default 1 75 V cell It is intended to stop or limit the vehicule operation when the battery is deeply discharged AC input connected Terminals 1 and 7 This contact is NC normally closed and it opens when the AC line is connected to the charger It is intended to prevent the vehicule from moving while the AC input plug is...

Страница 4: ...he AC input will be recovered the charger will restart the charge cycle automatically EQUALIZE MAINTENANCE These functions are useful to keep the battery in perfect condition and to extend its life even when it s not used for a long period weeks months It is sufficient to leave the battery connected to the charger After a normal termination of the charge it is sufficient to leave the battery conne...

Страница 5: ...charger will suspend the charge and the LED Charge complete will turn on At this time it s possible to disconnect the battery ERROR SIGNALS If a faulty condition is detected the charger will stop automatically and generate a fault signal DEFECTIVE OR INCORRECT BATTERY Both LEDs flashing CHARGING FAILURE Both LEDs remain in ON state www Tecnikcharger com End of Manual ...

Отзывы: