Instruction Manual
TE470/TE480
S.p.A.
CYCLE WITH PRE-WELD, SLOPE UP, AUTOMATIC STROKE, AUTOMATIC CYCLE
NUMBER PARAMETER VALUE
TO WORKING
MODE
PW%
B CONTROL
MODE
NO
C STROKE
AUTOMATIC
1
SQUEEZE 1
20 cycles
2 SQUEEZE
30
cycles
3 PRE-WELD
08
cycles
4
POWER 1
20 %
5
COLD 1
10 cycles
6
SLOPE UP
04 cycles
7 WELD
12
cycles
8 POWER
60
%
9 IMPULSE
N.
01
10
COLD 2
00 cycles
11
SLOPE DOWN
00 cycles
12
COLD 3
00 cycles
13 POST-WELD
00
cycles
14
POWER 2
05 %
15
HOLD TIME
09 cycles
16
OFF TIME
40 cycles
01
02
03
05
06
07
15
16
1
04
2
08
02
CYCLE WITH PRE-WELD, AUTOMATIC STROKE, AUTOMATIC CYCLE, WITHOUT COLD TIME BETWEEN PRE-WELD
AND WELD (COLD 1 TIME =00)
NUMBER PARAMETER VALUE
TO WORKING
MODE
PW%
B CONTROL
MODE
NO
C STROKE
AUTOMATIC
1
SQUEEZE 1
20 cycles
2 SQUEEZE
30
cycles
3 PRE-WELD
08
cycles
4
POWER 1
20 %
5
COLD 1
00 cycles
6
SLOPE UP
00 cycles
7 WELD
12
cycles
8 POWER
60
%
9 IMPULSE
N.
01
10
COLD 2
00 cycles
11
SLOPE DOWN
00 cycles
12
COLD 3
00 cycles
13 POST-WELD
00
cycles
14
POWER 2
05 %
15
HOLD TIME
09 cycles
16
OFF TIME
40 cycles
01
02
03
07
15
16
1
04
2
08
02
COMPLEX CYCLE WITH PRE-WELD, SLOPE UP, PULSES, AUTOMATIC STROKE, AUTOMATIC CYCLE
NUMBER PARAMETER VALUE
TO WORKING
MODE
PW%
B CONTROL
MODE
NO
C STROKE
AUTOMATIC
1
SQUEEZE 1
30 cycles
2 SQUEEZE
20
cycles
3 PRE-WELD
08
cycles
4
POWER 1
20 %
5
COLD 1
10 cycles
6
SLOPE UP
04 cycles
7 WELD
12
cycles
8 POWER
60
%
9 IMPULSE
N.
02
10
COLD 2
06 cycles
11
SLOPE DOWN
00 cycles
12
COLD 3
00 cycles
13 POST-WELD
00
cycles
14
POWER 2
05 %
15
HOLD TIME
09 cycles
16
OFF TIME
40 cycles
01
02
03
05
06
07
10
07
15
16
1
04
2
08
09
08
02
33/52