2.3 – CONSTANT CURRENT OPERATING MODE
When the weld control unit works in constant current operating mode (parameter WORKING MODE selected in
IK), the current value with which to perform the weld is set directly. During the weld, the control unit measures
the weld current's real effective value (RMS) in every half-period and maintains the set current according to a
mathematical correction algorithm.
In addition to simplifying the programming operations, this operating mode also permits to keep the desired
welding current even if some factors change such as: mains voltage, welding circuit dimensions and impedance,
conditions of the welding tools or surface condition of the materials being processed.
CONSTANT CURRENT OPERATING MODE SURVEY
Welding current (I) variation according to the mains
voltage (V) variation in standard working mode 80%
Welding current (I) variation according to the mains
voltage (V) variation in constant current 80% mode
14/52