TRIGGER LEVEL - For changing the sensitivity with which the
instrument recognises the start of the welding process. High
sensitivities enable low current or force values to be measured
correctly. While lower sensitivities allow measurements to be
performed in environments with high electrical disturbance or
mechanical vibration.
FORCE FILTER - For activating a filter on the disturbances present on
the force measurement, which can occur in the presence of an
electrical axis.
TRIGGER TYPE - The instrument normally receives the welding process
start signal on both the current and the voltage channel; one of the
two channels may be excluded from receiving the welding process
start signal.