![TECNA TE1700 Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/tecna/te1700/te1700_user-manual_1071489019.webp)
TECNA WELD TESTER TE1700
Force: supplies the maximum force F
max
during welding, at the
beginning F
on
of the welding and at the end F
off
of the welding process.
If CONTINUOUS mode is selected, the data viewed cannot be edited by
the user. The data displayed are:
•
RMS value of the welding current I
RMS
•
Positive current peak I
PEAK+
•
Negative current peak I
PEAK-
•
RMS value of the secondary voltage V
RMS
•
Positive voltage peak V
PEAK+
•
Negative voltage peak V
PEAK-
•
Continuous force value
In this case the force values are updated continuously and
automatically.
PAGE 19