background image

5

3.1 

If the assessment is positive the voltage remains limited at 16V and the DESULFATE LED #3 remains on. 

3.2 

If the assessment is negative, typically for a badly neglected battery that has not received any charge for many months, 
the second more powerful TURBO stage will engage with the voltage limit reset to 22V. TURBO RECOVERY mode is 
indicated by a fl ashing DESULFATE LED #3. 

3.3 

Once the battery accepts the very low set current (0,4A LED #8 indicating) the voltage will reduce until the moment 
when the automatic circuit judges that the battery can accept the fi nal stage of the recovery programme. If the 
DESULFATE LED #3 was fl ashing during the TURBO mode (§3.2), it will now revert to steady indication. During 15 
minutes the 

ampmatic

 current control will now deliver current in pulses (as displayed by LEDs #8, 9 and 10) 

whilst maintaining the voltage below 14,3V, to further prepare the battery to accept normal charge. This mode is 
particularly effective for initiating recovery of factory activated / “hi performance” pure lead or cyclic cell AGM batteries. 

NOTE:

 If the battery remains connected to the vehicle electrical system (even with ignition key in off position) the TURBO 

recovery stage cannot engage.

4. Bulk and pulsed absorption charge

The BULK CHARGE stage (steady LED #4) will engage if the micro processor determines that the battery can accept 
charge at normal voltages levels.

4.1 

The 

ampmatic

 charge current monitoring and control mode automatically determines the most effi cient rate of 

charge current for the connected battery, according to its state of charge, state of health, and electrical storage 
capacity. The delivered current may be anywhere from 0,4A to 5A. For most discharged (but not totally fl at) batteries of 
rated capacity 12Ah or more, CURRENT LED #10 should also light up.

4.2  

The PULSED ABSORPTION stage (fl ashing CHARGE LED #4) starts when the voltage has reached 14,3V for the fi rst time 
during BULK CHARGE stage. The 

ampmatic

™ current control circuit now delivers pulses of current for 10 minutes 

so as to cause the battery voltage to vary between 13,7V and 14,3V, to equalise the individual cells within the battery 
and bring it to full charge as rapidly as possible. Charge current LED #8 and possibly #9 (

ampmatic

™) and #10 

(5A) will light when current is delivered.

4.3  

CHARGE VERIFICATION (fl ashing LED #4) follows PULSED ABSORPTION. The charging voltage is now limited at 13,6V 
during 5 minutes whilst the battery’s charge level is verifi ed. If the battery requires further charging (indicated by the 
0,4A charge current LED pulsing strongly) the programme will revert to the PULSED ABSORPTION stage (§ 4.2). These 
reversions may occur as many times as is necessary to reduce the battery’s current demand below 400mA at 13,6V 
(which is consistent with a battery that has accepted as much charge as its basic condition allows). 

As soon as the 

circuit has verifi ed that the charge is adequate the voltage retention test (see § 5) automatically follows. 

NOTE 1

 For safety reasons there is an overall time limit of 48 hours for programme stages 3.1 through 4.3.

5. 6. 7. Initial and extended voltage retention tests and battery maintenance 

charging

During the VOLTAGE RETENTION TEST delivery of current to the battery is interrupted to allow the circuit to monitor the 
battery’s voltage decline to determine its ability to retain charge and deliver power. 

The initial 30 minute VOLTAGE RETENTION TEST follows § 4.3 during which a small load of 100mA is applied to improve the 
accuracy of the result. For batteries with a good state of health the green TEST LED #5 should fl ash at the start and continue 
throughout the test period, otherwise LEDs #5 + 6 or 6 or 6 + 7 or 7 will fl ash and indicate voltage measured during the test 
(see table below). 

INTERPRETATION OF POSSIBLE LED INDICATIONS DURING OR AFTER THE VOLTAGE RETENTION TEST: 

RED #7

RED #7 + 
YELLOW #6

YELLOW #6

YELLOW #6 + 
GREEN #5

GREEN #5

BATTERY TYPE

VOLTAGE BELOW 
12,2V

VOLTAGE 12,2 
– 12,4V

VOLTAGE 12,4 
– 12,5V

VOLTAGE 12,5 
– 12,7V

12,7V +

WITH FILLER 
CAPS

READ NOTE 
BELOW

REPLACE

MAY NEED 
REPLACING SOON

GOOD

VERY GOOD

AGM SEALED MF

READ NOTE 
BELOW

REPLACE NOW

REPLACE

MAY NEED 
REPLACING SOON

GOOD

GEL SEALED MF

READ NOTE 
BELOW

REPLACE NOW

REPLACE

MAY NEED 
REPLACING SOON

GOOD

If the result after the initial 30 minute voltage retention test is anything other than green LED #5, the LED(s) fl ashing at that 
moment will now remain on, indicating the result is locked and testing has been concluded and a MAINTENANCE CHARGING 
cycle has started. 

EXTENDED VOLTAGE RETENTION TEST: 

If only the GREEN LED #5 is fl ashing at the end of the initial 30 minute voltage 

retention test, the test will be extended, indicated by the LED fl ashing mode changing from single pulse 
(- - - -) to double pulse (-- -- --). The extended voltage retention test checks for excessive self discharge (caused by the battery 

Содержание Optimate 6 AmpMatic TM180

Страница 1: ...ONS FOR USE IMPORTANT Read completely before charging Automatic charger for 12V lead acid batteries 1 x 12V STD AGM MF GEL CYCLIC CELL 15 240Ah 48 hour charge MODEL TM180 AC 220 240VAC 50 60Hz 0 85A DC 5 0A 12V ...

Страница 2: ...uble flash 12 hour test Full on Maintenance charge is delivered and TEST result is displayed LED 1 AC power present LED 2 Battery connected in reverse polarity LED 3 Full on Low voltage low current or pulse desulfation Flashing Turbo high voltage desulfation LED 4 Full on Bulk Charge Flashing Final Charge verification WORKSHOP TOOLS PROFESSIONAL BATTERY CARE Other TecMate Products info www tecmate c...

Страница 3: ...sable and longer service life will be obtained by minimizing such exposure Failure of the charger due to oxidation resulting from the eventual penetration of liquid into the electronic components connectors or plugs is not covered by warranty BATTERY CONNECTIONS 2 interchangeable connection sets are available supplied with the charger is a set of battery clips for charging the battery off vehicle ...

Страница 4: ...power the control circuitry and LED display The power converter is switched off when the charger is not connected to a battery resulting in a very low power draw of less than 1 7W equivalent to power consumption of 0 042 kWh per day When a battery is connected to the charger power consumption depends on the current demand of the battery and its connected vehicle electronic circuitry After the batt...

Страница 5: ...CATION flashing LED 4 follows PULSED ABSORPTION The charging voltage is now limited at 13 6V during 5 minutes whilst the battery s charge level is verified If the battery requires further charging indicated by the 0 4A charge current LED pulsing strongly the programme will revert to the PULSED ABSORPTION stage 4 2 These reversions may occur as many times as is necessary to reduce the battery s curre...

Страница 6: ...inute float charge periods followed by and alternating with a 30 minute rest periods during which there is no charge current This 50 duty cycle prevents loss of electrolyte in sealed batteries and minimizes gradual loss of water from the electrolyte in batteries with filler caps and thereby contributes significantly to optimizing the service life of irregularly or seasonally used batteries The circui...

Страница 7: ...gation of the purchaser to forward the unit together with proof of purchase see NOTE transportation or mailing costs prepaid to the manufacturer or its authorized representative This limited warranty is void if the product is misused subjected to careless handling or repaired by anyone other than the factory or its authorized representative The manufacturer makes no warranty other than this limite...

Страница 8: ...MOUNTING NOTICE 4x 4 5mm L 20mm 2m max 2m SAE 73 2 5m 4 5m max SAE 73 ...

Страница 9: ...copyright 2011 TecMate International TM180 IN1 110225_EN_A4 Discover our full range of accessories at optimate1 com C H A RGE C O N NECTO R C O N NECTO R P O W ER P O W ER ...