background image

4

example, with white matter between the plates, plates touching). If mechanical defects are apparent do not attempt to 
charge the battery, have the battery professionally assessed. 

5.

 

If the battery is new

, before connecting the charger read the battery manufacturer’s safety and operational instructions 

carefully. If applicable, carefully and exactly follow acid fi lling instructions. 

USING THE OPTIMATE 6: PROCEEDING TO CHARGE 

For safety reasons, the OptiMate output will only activate if a battery retaining at least 2V is connected

, whereupon the 

micro processor instantly diagnoses the battery condition and engages the appropriate charge mode and lights the 
corresponding charge status LED. 

The charger’s special recovery mode cannot engage if it senses that the battery is still connected to a vehicle wiring 
circuit 

which effectively offers a lower electrical resistance than the battery on its own. However, if the deep-discharged 

battery is not removed for recovery, neither battery nor vehicle electronics will be damaged.

VERY FLAT NEGLECTED BATTERIES: 

 

Pay particularly close attention to the following which is especially 

important for relatively small batteries such as those used on motorcycles, lawn tractors, jet-ski’s, snowmobiles and 
similar: 

A battery left deep-discharged for an extended period may develop permanent damage in one or more cells. Such 

batteries may heat up excessively during high current charging. 
Monitor the battery temperature during the fi rst hour, then hourly there-after. Check for unusual signs, such as bubbling or 
leaking electrolyte, heightened activity in one cell compared to others, or hissing sounds. If at any time the battery is 
uncomfortably hot to touch or you notice any unusual signs, DISCONNECT THE CHARGER IMMEDIATELY. 

ECO POWER SAVING MODE WHEN THE CHARGER IS CONNECTED TO AC SUPPLY: 

To reduce long term power 

consumption OptiMate 6 employs two converter circuits, a power converter to charge the battery and an auxiliary converter to 
power the control circuitry and LED display. The power converter is switched off when the charger is not connected to a battery 
resulting in a very low power draw of less than 1,7W, equivalent to power consumption of 0,042 kWh per day. When a battery 
is connected to the charger power consumption depends on the current demand of the battery and its connected vehicle / 
electronic circuitry. After the battery has been charged and the charger is in long term maintenance charge mode (to keep the 
battery at 100% charge) the total power consumption is estimated to be 0,060 kWh or less per day. 

The LED indicators referred to below, and the clauses dealing with them, are sequenced as they may come on through 
the course of the programme. 

FINAL

TURBO

AMPS

1

3

4

2

5

6

7

ampmatic

LED #10

LED #8

LED #9

LEDs #5, 6 & 7

LEDs #1 & 2

LEDs #3 & 4

1 and 2. INVERSE connections and input power

1. 

Connect the charger to a mains supply socket providing AC supply of 220 to 240V. The “POWER ON” LED #1 
should illuminate and LEDs  #3,4,5,6,7 should blink twice to confi rm micro processor health.

 

HIGH and LOW intensity indication: The "POWER ON" LED #1 will reduce intensity to a low level to indicate low power 
"ECO" mode. This will occur if there is no battery connected, or when a battery is connected and the programme fi nds 
itself in the Initial and Extended voltage retention test mode or the 'rest' periods of Maintenance Charge mode. The 
"POWER ON" LED #1 will indicate brightly during Recovery charge, Bulk and Pulsed absorption charge and 
Maintenance charge modes.  

2. 

If the INVERSE POLARITY LED #2 indicates, the battery connections are incorrect. The charger is electronically protected 
so no damage will result, and the output will remain disabled until the connections are corrected. 

3. Recovery charge

If the battery is extremely fl at (deep-discharged and sulphated), the recovery mode will engage and the DESULFATE 
LED #3 will light.

 A special high voltage is applied to force a very small fi xed current into the battery in a recovery attempt that 

may last for a maximum of two hours. Initially the voltage is limited to about 16V for 5 seconds while the circuit assesses 
whether this level is suffi cient to recover the battery. 

Содержание Optimate 6 AmpMatic TM180

Страница 1: ...ONS FOR USE IMPORTANT Read completely before charging Automatic charger for 12V lead acid batteries 1 x 12V STD AGM MF GEL CYCLIC CELL 15 240Ah 48 hour charge MODEL TM180 AC 220 240VAC 50 60Hz 0 85A DC 5 0A 12V ...

Страница 2: ...uble flash 12 hour test Full on Maintenance charge is delivered and TEST result is displayed LED 1 AC power present LED 2 Battery connected in reverse polarity LED 3 Full on Low voltage low current or pulse desulfation Flashing Turbo high voltage desulfation LED 4 Full on Bulk Charge Flashing Final Charge verification WORKSHOP TOOLS PROFESSIONAL BATTERY CARE Other TecMate Products info www tecmate c...

Страница 3: ...sable and longer service life will be obtained by minimizing such exposure Failure of the charger due to oxidation resulting from the eventual penetration of liquid into the electronic components connectors or plugs is not covered by warranty BATTERY CONNECTIONS 2 interchangeable connection sets are available supplied with the charger is a set of battery clips for charging the battery off vehicle ...

Страница 4: ...power the control circuitry and LED display The power converter is switched off when the charger is not connected to a battery resulting in a very low power draw of less than 1 7W equivalent to power consumption of 0 042 kWh per day When a battery is connected to the charger power consumption depends on the current demand of the battery and its connected vehicle electronic circuitry After the batt...

Страница 5: ...CATION flashing LED 4 follows PULSED ABSORPTION The charging voltage is now limited at 13 6V during 5 minutes whilst the battery s charge level is verified If the battery requires further charging indicated by the 0 4A charge current LED pulsing strongly the programme will revert to the PULSED ABSORPTION stage 4 2 These reversions may occur as many times as is necessary to reduce the battery s curre...

Страница 6: ...inute float charge periods followed by and alternating with a 30 minute rest periods during which there is no charge current This 50 duty cycle prevents loss of electrolyte in sealed batteries and minimizes gradual loss of water from the electrolyte in batteries with filler caps and thereby contributes significantly to optimizing the service life of irregularly or seasonally used batteries The circui...

Страница 7: ...gation of the purchaser to forward the unit together with proof of purchase see NOTE transportation or mailing costs prepaid to the manufacturer or its authorized representative This limited warranty is void if the product is misused subjected to careless handling or repaired by anyone other than the factory or its authorized representative The manufacturer makes no warranty other than this limite...

Страница 8: ...MOUNTING NOTICE 4x 4 5mm L 20mm 2m max 2m SAE 73 2 5m 4 5m max SAE 73 ...

Страница 9: ...copyright 2011 TecMate International TM180 IN1 110225_EN_A4 Discover our full range of accessories at optimate1 com C H A RGE C O N NECTO R C O N NECTO R P O W ER P O W ER ...

Отзывы: