Tecma Nano Owner’s & Installation Manual
4
www.thetfordmarine.com
Dimensions
Weight : 37,5 lbs.
Fig. A
Electrical System
Wire Gauge Size Chart
If Wire Gauge for distance from source* is:
0-20 feet
20-32 Feet
33-50 feet
Circuit
Breaker
12 VOLTS - Install
10 Gauge
8 Gauge
6 Gauge
30 amp
24 VOLTS - Install
16 Gauge
14 Gauge
12 Gauge
30 amp
* Distance measured assumes power and ground wires
Note:
Ceramic base dimensions may vary slightly in size.
■
All circuits must follow ABYC/ISO standards.
■
Wire gauge sizes must follow Wire Gauge Size Chart.
■
Every toilet must have its own circuit breaker or fuse.
■
Always use crimp-style connectors with Sealing provisions to avoid corrosion.
DANGER!
FIRE HAZARD:
Failure to use ABYC/ISO recommended circuit breakers or fuses can result in fire!
Fig. B
Note:
To install the Tecma Nano toilet, you MUST have the toilet and one of the Harness Kits pictured below!
(1x)
4
Fig. C
AR
T00198-1a
AR
T00198
(2x) 1/4” 10 x 2.5”
2
(2x) 1-1/4” x 2
3
1