Fusion color 18 FC rgbw
Cod. 7114745905 v 1.1 IT/EN
Pagina
8
Connections
The fixture is fitted with a power supply cable and two XLR 5 Pole connectors for DMX IN and OUT signal (Fig.1)
Any modification to this fixture, without authorization, is forbidden.
This lantern must be powered according to the voltage and frequency showed on its label (100/240V 50/0Hz). Connect the power cable
to the socket. We suggest to connect each projector to its own switch so that they can be individually switched on with a remote
control.
To remote control the projectors is required the use of a DMX512 control desk.
For the connection of signal use cable EIA rs-485 type: two core screened, 120
Ω
characteristic impedance, 22-24 AWG, low capacity, 1
XLR 5 poles MALE connector and 1 XLR 5 poles FEMALE connector.
To form a DMX chain, connect the DMX control desk to the first projector’s DMX IN, then from its DMX OUT to the DMX IN of the
second projector and so on.
For a correct functioning of the DMX signal, it is necessary to put a terminal into the DMX OUT of the last projector. This terminal is
made of 1 XLR MALE connector with a 120
Ω
resistance welded between PIN 2 and PIN 3.
Addressing of the fixture
In order to individually control several Fusion Color, it is necessary to assign to each item a different DMX address. Set the starting
channel taking into consideration that one Fusion Color needs 8 channels (4 or 5 or 7 or 8 or 13 channels depending on the functioning
mode the fixture is supposed to run).
For example, if you have 6 fixtures, it will be necessary to set them on the channels 1, 9, 17, 25, 33, 41.
To set the DMX channel press buttons ‘UP’ or ‘DOWN’ until you can see ‘Address’ on the display, then press ‘ENTER’. Change the DMX
address using the ‘UP’ ‘DOWN’ keys and then press ‘ENTER’ to confirm.
Functioning options
Via the digital display, it is possible to change the functioning options, to drive the fixture in stand alone mode with presets or programs
and with Master/Slave functions, to change or to create new programs, to display fixture information and to reset settings to default.
Power supply connection:
Supply: 100/240V 50/60Hz
Fuse: T 3.15 A 250 V
DMX connector:
1: GND (screen)
2: data –
3: data +
4: NC
5: NC
Fig. 1
Address
00001
EN
DMX OUT
DMX IN