127
z
Event type: There are several options for you such as disk error, no disk, disconnection,
IP conflict and etc.
z
Alarm output: Please select alarm activation output port (multiple choices).
z
Latch: Here you can set corresponding delaying time. The value ranges from 10s-300s.
System automatically delays specified seconds in turning off alarm and activated output after
external alarm cancelled.
z
Show message: system can pop up the message in the local screen to alert you when an
alarm occurs.
z
Alarm upload: System can upload the alarm signal to the network (including alarm centre)
if you enabled current function.
z
Send email: System can send out email to alert you when an alarm occurs.
z
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.
Figure 5-87
5.7.3
Alarm
Output
Here is for you to set proper alarm output.
Please highlight icon
to select the corresponding alarm output.
After all the setups please click OK button, system goes back to the previous menu. See Figure
5-88.
Figure 5-88
5.7.4
Manual
Record
Содержание Elite Mini Series NVR-ELM-16-DH
Страница 59: ...110 Figure 5 55 Figure 5 56 Figure 5 57...
Страница 83: ...134 Figure 5 100...
Страница 149: ...200 Teclast Ti Cool 512M Teclast Ti Cool 1G Teclast Ti Cool 2G...