General Trouble Shooting by
Technician
Blower Motor Does Not Operate
Possible Cause
Inspection
Solution
1. Blown Fuse
Inspect fuse/wiring
Replace fuse/wiring
2. Broken wire or bad
connection.
Check the fan motor for
ground and connections.
Repair wiring or connector
3. Fan motor malfunction
Check the lead wires from the
motor with a circuit tester
Replace Motor
4. Fan motor switch
malfunction
Check power into and out of
the switch
Replace fan switch.
Blower Motor Operates Normally, Bur Air Flow is Insufficient
Possible Cause
Inspection
Solution
1. Evaporator inlet obstructed
Check evaporator for
obstruction
Remove obstruction and clean
fins with air or water
2. Defective thermo switch,
(frozen Evaporator)
Check thermostat using a circuit
tester
Replace thermostat
Insufficient cooling, does not operate at all, or operates improperly
Possible Cause
Inspection
Solution
1. System low on refrigerant
The high side pressure will be
low.
Repair any leaks evacuate
and charge.
2. Excessive Refrigerant
The high side pressure will be
high
Recover refrigerant and weigh
in correct charge
The compressor does not operate at all, or operates improperly
Possible Cause
Inspection
Solution
1. Loose drive belt
The belt is vibrating, slipping
Adjust tension
2. Internal compressor
malfunction
The compressor is locked up
and the belt slips
Replace compressor
3. Low battery voltage
Clutch slips
Inspect charging battery
charging system
4. Faulty coil
Clutch slips
Replace clutch
5. Oil on the clutch
Clutch slips
Replace or clean clutch
surface
6. Open coil
Clutch does not engage
Replace clutch
7. Broken wiring or poor
ground
Clutch will not engage
Inspect ground and connection
and repair
8. Wiring Harness components Test the conductance of the
HP Binary Switch, thermostat,
etc
Repair or replace parts
53
1
APPENDIX
c O m F O r t A i r e A / c s Y s t e m s
c c
8 0
Содержание ComfortAire
Страница 1: ...TechPlus TechPlus S E R V I C E S U P P L E M E N T ComfortAire ComfortAire AIR CONDITIONING SYSTEMS...
Страница 5: ...lTechPlus s e r v i c e s u p p l e m e n t...
Страница 24: ...Typical TM 21 Compressor Manual Control Panel 23 1 APPENDIX C O M F O RT A IRE A C S Y STEMS c c 8 0...
Страница 50: ...49 1 APPENDIX C O M F O RT A IRE A C S Y STEMS c c 8 0...
Страница 80: ...79 Notes n o t e s...
Страница 81: ...lTechPlus s e r v i c e s u p p l e m e n t 80 Notes...
Страница 82: ...81 Notes n o t e s...
Страница 83: ...lTechPlus s e r v i c e s u p p l e m e n t 82 Notes...
Страница 84: ...83 Notes n o t e s...