UPS ERA LED 1.5 – 2-0 – 2.6 

 

Safety Warnings 

 

 

 

Read this manual carefully and completely before installing and using the TECNOWARE ERA LED 
Uninterruptible Power Supply, which, from here after, will also be referred to as UPS. 

 

This manual should be kept close to the UPS and read before the UPS is installed and used. 

 

The  UPS  must  be  used  only  by  properly  trained  personnel.  To  ensure  correct  and  safe 
operations,  it  is  necessary  that  operators  and  maintenance  personnel  observe  the  general 
safety Standards as well as the specific instructions included in this manual. 

 

Risk of electric shock: do not remove the cover. The UPS contains internal parts, which are at a 
high  Voltage  and  are  potentially  dangerous,  capable  of  causing  injury  or  death  by  electric 
shock. 

 

There are no internal parts in the UPS, which are user serviceable. Any repair or maintenance 
work  must  be  performed  exclusively  by  qualified  technical  personnel  authorized  by 
TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded.  

 

Warning  to  the  technical  personnel  authorized  for  Service:  since  internal  components  are 
connected to the batteries, they will remain powered, and therefore dangerous, even after the 
UPS  has  been  disconnected  from  AC  power  mains.  Before  any  repair  or  maintenance  work, 
disconnect the batteries, by removing the positive cable (red colour) from the positive pole of 
the battery.  

 

It is compulsory to ground the UPS according to Safety Standards. The AC mains power supply 
socket used to power the UPS must have an earth connection. 

 

In  the  event  of  AC  main  power  supply  failure  (when  the  UPS  works  in  Battery  mode),  do  not 
unplug the power supply cable to the UPS to ensure earth continuity to the connected loads. 

 

Since the AC mains power supply cable acts as a separation device, the AC mains power socket 
used to supply the UPS and/or the rear side of the UPS must be accessible to easily disconnect 
the cable in case of dangerous conditions. 

 

Risk of electric shock at the Output lines when the UPS is ON. 

 

Risk of electric shock at the Output lines while the unit is connected to the AC utility line. 

 

Do not obstruct ventilation slots or holes and do not rest any object on top of the UPS. 

 

Do not insert objects or pour liquids in the ventilation holes. 

 

Install the UPS indoors, in a protected, clean and moisture-free environment. 

 

Do not expose to the direct sun light. 

 

Do not keep liquids, flammable gases or corrosive substances near the UPS.  

 

 

 

Содержание ERA LED 1.5

Страница 1: ...Uninterruptible Power Supply ERA LED 1 5 ERA LED 2 0 ERA LED 2 6 User s manual...

Страница 2: ......

Страница 3: ...Characteristics 11 9 Maintenance 12 9 1 UPS Cleaning 12 9 2 Battery 12 9 3 Battery Replacement 12 9 4 Operator Safety 13 10 Troubleshooting 14 Conformity to the European Directives 15 Product Disposal...

Страница 4: ...he batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by removing th...

Страница 5: ...low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out with the most widespread operating systems Windows Mac OS X Linux etc R...

Страница 6: ...3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in case you need to send th...

Страница 7: ...front panel informs the user about operating status alarm conditions and measurements Front panel shown below consists of two parts 1 3 Leds that show the functioning modes alarm and fault conditions...

Страница 8: ...e 2 Figure 2 LCD Display 1 Line LED this blue led is always on in LINE mode 2 Battery LED this yellow led is on in BATTERY mode 3 Fault LED this FAULT led red switches on to indicate the excessive or...

Страница 9: ...OUT connectors to protect and filter a phone line an ADSL or a LAN TNV 3 type connections 6 Computer Interface USB connector it is the communication USB port The 2 ONLY FILTERED Output receptacles red...

Страница 10: ...at the UPS do not go in overload status otherwise it is necessary to remove part of the Output load 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode the Line...

Страница 11: ...Battery Led in yellow color and by an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode ERA LED indicates the Low Battery condition whenever the battery reaches a...

Страница 12: ...apter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition The UPS indicates the Fault condition by LCD display by lighting of the Fault led and...

Страница 13: ...Accepted Overload 130 Certifications CE Standards CEI EN 62040 1 2009 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 92 Battery Type Lead acid sealed free maintenance Number of bat...

Страница 14: ...ake in mind that batteries are recharged automatically if the UPS works in Normal mode or if the UPS is off and connected to the AC Input Line Battery life strongly depends on the ambient temperature...

Страница 15: ...tools or metal parts on top of batteries e Disconnect the charging source prior to connecting or disconnecting battery terminals f Determine if battery is inadvertently grounded If inadvertently groun...

Страница 16: ...colour from the positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button and check that is pushed Batteries are flat Recharge...

Страница 17: ...rban waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any...

Страница 18: ......

Страница 19: ......

Страница 20: ...TECNOWARE s r l www tecnoware com...

Отзывы: