6. Regulation 

 

From 01.01.2018, the EU conformity of these devices is additionally linked to the fulfillment of 

the Ecodesign requirements 2015/1188. 

The installation and commissioning of the devices is only permitted in conjunction with external 

room temperature controllers that fulfill the following functions: 

 

  electronic room temperature control 

 

and has at least one of the following properties: 

 

  room temperature control, with presence detection 

  room temperature control, with open window detection 

  with distance control option 

  with adaptive start control 

  with working time limitation 

  with black bulb sensor 

 

The following room temperature controller systems 

 

  RF Receiver together with the  TPF-Eco Thermostat (Art.Nr.: 750 000 641) and the Eco-

Interface (Art.Nr.750 000 640) or 

  DSM-Thermostat with the DSM-Interface (Art.No.:911 950 101) 

 

from Technotherm meet the following requirements and therefore the ErP Directive: 

 

  electronic room temperature control plus week timer (RF/DSM) 

  room temperature control, with open window detection (DSM) 

  with distance control option (DSM) 

  with adaptive start control (DSM) 

 

Use of the VPS / VP Standard range (without external thermostat control) is only permitted on feet. 

 

Installation of the receiver and the interfaces see separate instructions. For customer service - see last 

page. 

 

Failure to comply with these requirements will result in the loss of the CE mark. 

 

 

 

Содержание VP 1000

Страница 1: ...SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Edition 12 17 Id_Nr 911 360 870 Installation and technical manual VP VPS VPS H VPS DSM VPS RF with feet s GB Eco Design Directive 2015 1188 Feet using This product is only suitable for well insulated rooms or for occasional use ...

Страница 2: ...d the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended normal operating positi...

Страница 3: ...less than 1m of free space in front of the heater not located immediately below a socket outlet Do not leave animals or children touch or play with the appliance Do not use the heater in rooms with explosive gas or while using inflammable solvents or varnish or glues If the cordset is damaged and you have to change it do not do the job yourselves Take the product to an after sales authorised repai...

Страница 4: ...erating Frost Protection The heater is working in Frost Protection Array 7 C OFF The two parallel lines in the display indicate that the heater is still running 2 2 Normal Operation To turn the heating device on press the On Off key and select between the Comfort and Setback mode You can switch between the different modes by pressing the selector key until the desired token appears on the display ...

Страница 5: ...nto the Configuration mode see user manual transmitter Check that the indicator light is no longer flashing Application Example The use of a room thermostat in combination with a opening detector is ideal because the opening detector will detect if a window is open and will automatically switch to frost protection By pressing the receiver button for approximately 10 seconds you can change the rela...

Страница 6: ...t a safe place at all times Be sure to hand this manual to any other succeeding owner of the device The device comes with a power plug that has to be plugged into an outlet The device is designed to be connected to 230V nominal alternating current AC 5 2 Assembling the Feed Do not put the device near any inflammable items 1 Put the convector on a table or any other work surface 2 Align the holes y...

Страница 7: ...0 85 442 140 375 250 115 375 11 5 VPS DSM 1500 1500 1050 450 85 740 140 375 250 115 525 15 0 VPS DSM 2000 2000 1050 450 85 740 140 375 250 115 525 15 0 VPS RF 1000 1000 750 450 85 442 140 375 250 115 375 11 5 VPS RF 1200 1200 750 450 85 442 140 375 250 115 375 11 5 VPS RF1500 1500 1050 450 85 740 140 375 250 115 525 15 0 VPS RF 2000 2000 1050 450 85 740 140 375 250 115 525 15 0 VP 1000 1000 750 45...

Страница 8: ...orking time limitation with black bulb sensor The following room temperature controller systems RF Receiver together with the TPF Eco Thermostat Art Nr 750 000 641 and the Eco Interface Art Nr 750 000 640 or DSM Thermostat with the DSM Interface Art No 911 950 101 from Technotherm meet the following requirements and therefore the ErP Directive electronic room temperature control plus week timer RF...

Страница 9: ...rt control Yes with working time limitation No with black bulb sensor No Model VPS RF additional TPF Thermostat and Eco Interface necessary Item Symbol Value Value Item Value Heat output Type of heat input for electric storage local space heaters only select one Nominal heat output Pnom 1000 1200 1500 2000 Watt manual heat charge control with integrated thermostat No Minimum heat output indicative...

Страница 10: ...temperature control select one At minimum heat output elmin Watt single stage heat output and no room temperature control No In standby mode elSB Watt Two or more manual stages no room temperature control No with mechanic thermostat room temperature control No with electronic room temperature control yes electronic room temperature control plus day timer No electronic room temperature control plus...

Отзывы: