Other control options (multiple choice is possible)

Room temperature control with presence detection

NO

Room temperature control with detection of an opened window

NO

With remote control option

YES

With adaptive start control

NO

With limitation of heating time

NO

With a black lamp sensor

NO

Type: TT-KS S DSM / TT-KS N DSM / TT-KS H DSM (interface: optionally) TT-KS TDI/TT-KS- N TDI / TT-KS H TDI / TT-KS S plus / TT-KS N plus / TT-KS H plus

Designation

Symbol

Rate

Unit

Designation

Unit

Heating capacity

Type of heat supply, only for electrical storage heaters in rooms (select one 

type)

Nominal thermal 

output

P

nom

0.5

1.0

1.2

1.5

1.8

2.0

2.4

2.8

kW

Manual thermal charge control, with an integrated thermostat

NO

Minimal thermal 

output (indicative)

P

min

0.5

1.0

1.2

1.5

1.8

2.0

2.4

2.8

kW

Manual thermal charge control with acknowledgement of the 

room inside and /or outside temperature

NO

Maximum con-

tinuous thermal 

performance

P

max,c

0.5

1.0

1.2

1.5

1.8

2.0

2.4

2.8

kW

Electronic charge control with acknowledgement of the room 

inside and /or outside temperature

NO

Auxiliary current 

consumption

Heating power supported with a fan

NO

At nominal thermal 

output

el

max

0.5

1.0

1.2

1.5

1.8

2.0

2.4

2.8

kW

Type of heating power / room temperature Control (select one 

type)

At the minimum 

heating capacity

el

min

0.8

0.8

0.8

0.8

0.8

0.8

0.8

0.8

W

Single-stage heating capacity; no room temperature control

NO

At the standby 

mode

el

SB

0.8

0.8

0.8

0.8

0.8

0.8

0.8

W

Two or more manual stages, no room temperature control

NO

With mechanical room temperature control

NO

With electronic room temperature control

NO

Electronic temperature control in the room, depending on the 

time of day

NO

Electronic temperature control in the room, depending on the 

weekday

YES

Other control options (multiple choice is possible)

Room temperature control with presence detection

YES

Room temperature control with detection of an opened window

YES

With remote control option

NO

With adaptive start control

YES

With limitation of heating time

NO

With a black lamp sensor

NO

Contact

information:

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1 D-09217 Burgstädt, Germany

Содержание TT-KS 1200 S X4

Страница 1: ...and Operating Instructions Electrical Partial Thermal Storage Heater Feet Castors Please read attentively and keep in a safe place Subject to alterations Id_no 911 360 9650 Issue 04 18 Ecological Design Directive 2015 1188 Feet castors This product is only suitable for well insulated rooms or for occasional use ...

Страница 2: ...ur heaters is constantly supervised by a state accredited test centre This heater can be used by children aged from 8 years and above and by physically sensory or mentally restricted persons if they are supervised or given instructions on safe use and understand the hazards involved as it does not require any experience or knowledge This device is not a toy for children to play with Cleaning and u...

Страница 3: ...room tem perature drops the room thermostat switches ON the heater again This process is repeated continuously as long as the heater is at the operation mode If you are going to be absent for a longer period of time please set the temperature to a lower level to save energy If you turn the control knob completely to the left the heater will be switched OFF 2 2 Installation with internal temperatur...

Страница 4: ...cter than in dry rooms In addition to the already above mentioned provi sions of DIN VDE 0100 they have also comply with VDE 0100 701 Our bathroom radiators must be installed exclusively by an authorized and certified electrician All the instructions given in 3 1 shall be adhered to in full Exception Our bathroom heaters are additionally protected against expected moisture 4 Technical data Our sur...

Страница 5: ... 24 TT KS 1200 S X4 1200 68 x 63 x 7 IP 24 TT KS 1500 S X4 1500 98 x 63 x 7 IP 24 TT KS 800 N 800 68 x 34 x 7 IP 20 TT KS 1200 N 1200 98 x 34 x 7 IP 20 TT KS 1600 N 1600 128 x 34 x 7 IP 20 TT KS 2000 N 2000 158 x 34 x 7 IP 20 TT KS 800 N X4 800 68 x 34 x 7 IP 24 TT KS 1200 N X4 1200 98 x 34 x 7 IP 24 TT KS 1200 H 1200 38 x 124 x 7 IP 20 TT KS 1800 H 1800 55 x 124 x 7 IP 20 TT KS 2200 H 2200 68 x 1...

Страница 6: ...d the electric storage heater Remove the packaging Heed that no packaging residues stick on the heater Insert the rollers or feet from the bottom into the fins of the heater To ensure a secure standing pay attention to the same external distances 6 Report the case to the after sales service Your surface storage heater was carefully manufactured and checked repeatedly before dis patch If you should...

Страница 7: ...of day YES Electronic temperature control in the room depending on the weekday NO Other control options multiple choice is possible NO Room temperature control with presence detection Room temperature control with detection of an opened window NO With remote control option NO With adaptive start control NO With limitation of heating time NO With a black lamp sensor NO 7 1 Tables Type TT KS S RF TT...

Страница 8: ...indicative Pmin 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Manual thermal charge control with acknowledgement of the room inside and or outside temperature NO Maximum con tinuous thermal performance Pmax c 0 5 1 0 1 2 1 5 1 8 2 0 2 4 2 8 kW Electronic charge control with acknowledgement of the room inside and or outside temperature NO Auxiliary current consumption Heating power supported with a fan NO At ...

Отзывы: