6. Direct connection
Note: Fasten the screw nuts with caution, to avoid damage to the valves or the
piping system.
For direct connection, the two ½“ screw-in nipples and the ½“ seals must be
screwed into the ½“ union nuts of the hot-water and cold water connectors. The
two ½“ caps of the side outlets of the hot water and cold-water connectors must
be removed and screwed onto the open end of the screw-in nipples. The hot
water and cold-water connectors must then be screwed into the 3/8“ union nut of
the appliance and delivery pipe, together with the 3/8“ seals.
For direct connection, it is advisable to mount the appliance at a distance as
illus-trated alongside, using the spacer sleeves supplied. It should therefore be
noted that the two fixing holes near the lower pipe connections are also used.
The flared end of the pipes must be screwed into the ½“ side outlets of the
hot-water and cold-water connectors with ½“ union nuts and ½“ seals. The holes
required for the pipes must then be bro-ken out of the housing with the aid of a
blunt implement.
In case of direct connection please note: Put the strainer into the cold water
connection!