Technosoft 2019
15
iPOS360x VX-CAN/CAT Technical Reference
Remark:
In case of using a metallic box, with ventilation openings, all spacing values may be reduced substantially.
With proper ventilation, keeping the air surrounding the iPOS360x inside the limits indicated in
the spacing values may be reduced down to the mechanical tolerance limits of
Figure 3.4
Recommended spacing for vertical mounting, worst case: non-metallic, closed box
For ventilation holes / slots that pierce a metallic wall also used for EMI shielding, the maximum slot length d should be
less than λ/16, where λ is the wavelength corresponding to maximum filtered frequency (ff):
f
f
d
⋅
⋅
=
<
16
10
3
16
8
λ
If ventilation driven by natural convection is not enough to maintain the temperature surrounding the iPOS360x drive(s)
inside the limits indicated in
and
then alternate forced cooling methods must be applied.
3.3.2
Horizontal Mounting
When iPOS360x is mounted horizontally, its overall envelope (size) including the recommended mating connector is
shown in
. The iPOS360x has 6 fixing shoulders that may be used to secure the drive.
Figure 3.5
iPOS360X VX-CAN/CAT Overall dimensions for horizontal mounting
25 typ.
4
1
.2
ty
p
.
9.4 typ.
2.7 typ.
2.5 typ.
4 typ.
Figure 3.6
ECAT-VX adapter overall dimensions for horizontal mounting
All dimensions are in mm.