8.1
Place the Lokring tool over the Lokring
fitting
8. install the Lokring fitting
8.2
Note: keep out of the line of fire!
Pump until the driver of the Lokring fitting
touches the body
8.3
Open the release valve on the pump and
remove the Lokring tool
9.1
Check that the assembly has met the
following criteria:
• the driver is completely up against the
body of the fitting;
• the Lokring fitting is at the "inspect"
mark;
• the end of the Lokring fitting's body
protrudes from underneath the driver
9. check the assembly
05
questions? +31 343 492 090 • technom.com
stainless steel
installation