1166 UHF Reader User Guide V1.07
Copyright © 2019 Technology Solutions (UK) Ltd
24
MAINTENANCE
TROUBLESHOOTING
For trouble-free service please observe the following tips when using the 1166 UHF Reader:
●
Protect the 1166 UHF Reader from temperature extremes. Do not leave it on the dashboard of a car on a hot
day, and keep it away from heat sources.
TROUBLESHOOTING AND MAINTENANCE
Symptoms
Possible cause
Action
Nothing happens when the trigger
button is pressed.
If the LEDs are not on then the
battery may be flat.
Charge the 1166 UHF Reader.
The 1166 UHF Reader may have
button actions disabled.
Check the 1166 UHF Reader
configuration and restore to defaults
if unsure.
Other.
Work through
on TSL
®
Website
The orange LED flashes rapidly
when charging.
There is a battery fault.
Replace the battery pack.
The battery pack temperature is
outside recommended limits.
Ensure that charging only occurs
between 5°C and 40°C.
The host
Bluetooth
®
discovery does
not find the 1166 UHF Reader.
The 1166 UHF Reader has powered
off.
Press the trigger button and ensure
the blue LED is flashing.
The 1166 UHF Reader is out of
range.
Move the 1166 UHF Reader closer
to the host.
The
Bluetooth
®
friendly name of
the 1166 UHF Reader has been
changed.
Check the
Bluetooth
®
friendly name
or restore the 1166 UHF Reader to
factory defaults if unsure.
Opening the
Bluetooth
®
virtual com
port does not connect to the 1166
UHF Reader.
The host has paired to a different
Bluetooth
®
device.
Pair to the required 1166 UHF
Reader.
The host
Bluetooth
®
function has an
error.
Warm boot the host. If this does not
help, delete the 1166 UHF Reader
from the favourites list and re-pair.
Bluetooth
®
pairing fails.
The PIN on the 1166 UHF Reader
has been changed
Set the
Bluetooth
®
PIN to a known
value
Other symptoms.
Other fault.
and email result to
along with a description of the
problem.
www.tsl.com