Using the Software
MemoCam Manual
65
Each
input
can activate up to 3 cameras in
the MemoCam Plus and MemoCam DVR.
When several cameras are activated by a
single input, recording is performed in
sequence for activated cameras from
Camera 1 to Camera 3
When the
External Arm/Disarm
function
is activated for a particular input, no other
functions are available for that particular
input.
An external device (e.g. control
panel)connected to an
Input
can be used
for
External Arm/Disarm
function.
The
External Arm/Disarm
contact
can
be defined as Normally Closed (NC) or
Normally Open (NO) using the selector in
the column title.
Relay activation time
can be defined by
selecting the desired time in seconds in the
column title.
An
IR flash
can be activated by checking
the checkbox in the
Relay
column title. An
IR flashlight connected to MemoCam
Plus/DVR relay 2 output synchronizes with
frame capture.