Digitizer
Model: APV8516-14
Instruction Manual
1.0.1 Edition
March 2020
TechnoAP Co., Ltd.
2976-15 Mawatari, Hitachinaka-shi, Ibaraki 312-0012, Japan
TEL. +81-29-350-8011 FAX. +81-29-352-9013
http://www.techno-ap.com
Страница 1: ...gitizer Model APV8516 14 Instruction Manual 1 0 1 Edition March 2020 TechnoAP Co Ltd 2976 15 Mawatari Hitachinaka shi Ibaraki 312 0012 Japan TEL 81 29 350 8011 FAX 81 29 352 9013 http www techno ap co...
Страница 2: ...Edition 1 0 1 March 2020 2 42 TechnoAP Co Ltd...
Страница 3: ...or vibration to this device Do not disassemble or modify this device Do not wet this device with water or condensation Do not operate this device with wet hands If there is heat generation deformatio...
Страница 4: ...the following 1 Failure or damage due to misuse or improper repair or modification or disassembly 2 Failure and damage due to falling etc 3 Breakdown damage in harsh environments high temperature hig...
Страница 5: ...n 9 Power ON and IP Connection Confirmation 9 Connection 11 Setting of FAST filter 13 Setting of SLOW filter 14 Setting of Threshold 14 Window 16 Startup window 16 Config Tab 18 File Tab 25 Status Tab...
Страница 6: ...uipped with high speed high resolution ADC 500 MHz 14 bit The APV8516 14 can correspond to the high rates of more than 200 kcps per CH in the list mode with using the Gigabit Ethernet Gb Ether connect...
Страница 7: ...gram Mode List Mode Event Transmission Rate Approx 10 Mbyte sec In case of 10 Byte 80 Bit Event CH total is 1 Mcps 5 Communication I F LAN I F Ethernet TCP IP 1000 Base T List data acquisition UDP IP...
Страница 8: ...nal to adjust the time between boards 5 CLK O LEMO connector for external clock signal output Outputs a 25MHz TTL signal 6 CLK I LEMO connector for external clock signal input It can be operated using...
Страница 9: ...dministrator authority 2 Execute Setup exe in the Installer folder on the attached CD ROM Proceed with the installation interactively The default installation destination is C TechnoAP 3 Execute Start...
Страница 10: ...Edition 1 0 1 March 2020 10 42 TechnoAP Co Ltd Screen when communication settings are CORRECT Screen when communication settings are INCORRECT...
Страница 11: ...the PC is not inserted properly 3 The LAN cable on the device is not properly inserted 4 The power of this device remains OFF or the LAN cable is disconnected 5 The network setting on the PC is set t...
Страница 12: ...168 10 129 and RIGHT 192 168 10 130 Each clock IO and sync IO must be connected as follow Clock out of IP 130 module connect to clock input both IP 128 and IP 129 module Sync out of IP 130 module conn...
Страница 13: ...t of the FAST differential circuit in fast diff Select from ext 20 50 100 200 3 Constant setting of FAST system integration circuit Set the constant of the FAST system integration circuit with fast in...
Страница 14: ...ier to 0 to 100 of the rise time twice the value of the slowest rise 4 SLOW system pole zero setting The default value is 680 but it depends on the detector so set it to the optimal value with an osci...
Страница 15: ...ng of the threshold first input a somewhat large value other than 0 about 100 and observe the Input Rate Find a value that gradually reduces the threshold and increases the Input Rate Since that value...
Страница 16: ...histogram Save current histogram data to a file save wave Save the wave data save image Save this device screen as PNG format image quit Application termination Edit copy setting of CH1 Setting of CH1...
Страница 17: ...ag spectrum of CH1 and CH2 from time information of list data Device Choose the DPP for targeted measurement IP Address IP address IP address of the selected device will be display memo You can enter...
Страница 18: ...ain measurement purpose is direct anode signal from scintillator Energy data generate from integral of raw wave or filter wave Polarity This select the polarity of the input signal LLD Set the Lower L...
Страница 19: ...129 s 260 s Nomally set to 85 s Threshold Set the threshold Unit is digit Range is 0 to 8191 threshold rise edge Set above noise Timing Type Select the wavefrom for time stamp You can select the CFD w...
Страница 20: ...tiplying the input signal and CFD function It delay the input signal It add the two signal of the above Fig 4 2 3 How to use Constant Fraction Disicriminator Timing Timestamp timing is the same by CFD...
Страница 21: ...value for timestamp Nomally set 15 digits WALK Time Stamp QDC Sum or Peak Set the type of QDC data Type select from the PEAK and SUM PEAK is the peak value of raw signal SUM is the integral value of Q...
Страница 22: ...er200ns QDC Integral Range Set the integral time of QDC waveform Range is 0 ns from 32000 ns 100ns Integral range 200ns 0ns 8ns 0ns 8ns In case of Integral range 100ns In case of Integral range 200ns...
Страница 23: ...ow to calucurated FALL value total start cnt This is start position to calculate a total integral Set the range in front of the threshold Setting range is 1 to 498 498 ns 498 x 1 ns total stop cnt Thi...
Страница 24: ...re zero Set the pole zero of slow filter slow trigger thereshlold Set threshold of slow filter signal The unit is digit If upper this threshold on slow filter energy value be gifted from the peak of s...
Страница 25: ...is as follow Example histogram file path set C Data histogram csv histogram file save time sec set 10 Date is 2010 09 01 and 12 00 00 File name format of the start is C Data histogram_20100901_120000...
Страница 26: ...troid ch Calculated center value CH by the total of all counts peak count Maximum count gross count The sum of the count between ROI net count The sum of the count obtained by subtracting the backgrou...
Страница 27: ...ress You can see the compress waveform Wave Free Run ON is displayed the waveform of the trigger free OFF is displayed the waveform of the triggered Accumlation Select the accumulation of the waveform...
Страница 28: ...the area using the mouse And it will be zoom 2 X Zoom This will zoom along the X axis 3 Y Zoom This will zoom along the Y axis 4 Fit Zoom This will be auto scale 5 Zoom out to center a point Click a...
Страница 29: ...s Label will be changed by the setting ch Display unit is ch eV Display unit is eV If you set the two ROI it run a two point calibration X axis will be converted to the unit eV by the slope and interc...
Страница 30: ...t sec Real Time Real Time Start Time Measurement Start Time End Time Measurement End Time Be saved each CH POL Polarity TGE Waveform display trigger CH TGC Waveform trigger polarity RJT Waveform getti...
Страница 31: ...s at calculated Gross cps Gross cps at calculated Net count Sum counts that attracted a background Net cps Cps that attracted a background FWHM ch Full width at half maximum ch FWHM Energy resorution...
Страница 32: ...nd Time Be saved each CH POL Polarity TGE Waveform display trigger CH TGC Waveform trigger polarity RJT Waveform getting threshold CCF CFD Function CDL CFD Delay CWK CFD Walk CTH CFD Threshold FLK Bas...
Страница 33: ...DC 7 0 71 64 TDCFP 7 0 63 61 0 60 48 Energy 12 0 47 0 46 36 0 35 32 CH 3 0 31 16 FALL 15 0 15 0 TOTAL 15 0 Fig 5 3 1 List Data 128 Bit Bit127 to Bit72 TDC counts 56 Bit 1Bit 2 ns Bit71 to Bit64 TDCFP...
Страница 34: ...3 1 List Data 128 Bit Bit127 to Bit73 TDC counts 53 Bit 1 Bit 16 ns Bit72 to Bit69 TDCFP counts 4 Bit 1 Bit 1 ns Bit60 to Bit48 Energy 13 Bit Bit47 Selected proceccer type 0 DPP 1 DSP Bit35 to Bit32...
Страница 35: ...nment of energy spectrum measurement Make sure that all the devices VME rack HV high voltage power supply PC are OFF Connect the detector and HV with the SHV connector cable Connect the anode output s...
Страница 36: ...ctor input in the waveform mode In the config tab make the following settings and then click the Config menu Setting of waveform measurement Open the wave tab and check the settings shown below then c...
Страница 37: ...aseline Next uncheck wave free run gradually raise threshold from around 10 and keep a note of the threshold value that can capture the waveform firmly as shown in the previous page We will use this m...
Страница 38: ...b Config tab Open the spectrum tab and check the settings shown below then click the menu Clear Start After execution the following spectrum will be displayed Energy spectrum measurement Please note t...
Страница 39: ...ower supply and apply a voltage corresponding to the detector In this example Cs 137 source is used Confirm input waveform confirmer the same as above in 6 1 Energy spectrum measurement in histo mode...
Страница 40: ...o list config tab To save the list data set the following items in the file tab List save Check List file path Reference file path List file number Any value from 0 to 999999 Be careful not to duplica...
Страница 41: ...lated to list data in file tab Click the menu Config Clear Start After execution if the event is detected and the list data is acquired the following file size Byte will increase list data measurement...
Страница 42: ...AP Co Ltd TechnoAP Co Ltd Address 2976 15 Mawatari Hitachinaka shi Ibaraki 312 0012 Japan TEL 81 29 350 8011 FAX 81 29 352 9013 WEB http www techno ap com E mail order techno ap com Business Hour Mond...