Switching-on the receiver

1. Switching-on the receiver

When the receiver is switched on, the display shows the following sequence: manufacturer’s 

trademark (logo) «TECHNO-AC», Business card of the Receiver with the Software version number 
and the Start window (fig.А.1).

When  switching  the  receiver  with  the  button 

    while 

holding

 button  , after Business card  Window of network 

frequency  selection  will  appear.  Frequency  of  50  Hz  or 
60 Hz is selected by any of button

 ◄/►

, and «input» with 

transfer to Start window is performed by pressing the button again  .

2. The start window

The start window displays the following information:

Fig.А.1

voltage indicator

When power voltage 

4.0V after 

switching on the warning signal 

is heard,  when power voltage 

 

3.8V  there is the image of fully  

discharged battery 

 and the 

device will automatically 

switch off after

type of the sensor 

connected

   

  

Sensor not connected

   

   Acoustic sensor(AD)

  

  Electromagnetic sensor(EMD)

type of signal received

when working with AD

 

- «sound of liquid leakage (continuous acoustic signal)

 

- «sound generated by an impact (acoustic impulses during transmitter 

operation)

During work with electromagnetic sensor

 -continuous signal from the power network, cathode protection of 

trace  generator

 

 - pulsed signal of trace generator

  

 - Dual-frequency signal of the trace generator

indicator backlighting intensity

There are four levels of indicator 

backlighting intensity 

 

/

 / 

/  

Fig. А.2

parameters of detector of 

harmonic component with net 

frequency 

№ and frequency of harmonic 

component of net frequency (for the 

second filter)

indicators of  used buttons

Type of signal received, available 

for this of the sensor is selected 

by 

▲/▼ 

 buttons

№ of harmonic component of 

the net frequency (for the second 

filter) is selected by buttons   

/

 

Indicator backlighting intensity is 

selected by the buttons

◄/►

Return to the Start Window from measurement mode is performed by pressing 

  ((pause 

mode) and  

 .

Содержание Success AT-407N

Страница 1: ......

Страница 2: ...f operation Water leak detector Success 407N is designed for water leak detection from metal or plastic pipelines at depths of up to 6 m underground water leak detection from the pipelines inside the...

Страница 3: ...5 filter button broadband on off 12 headphones jack 6 memory button 13 sensors connector 7 start pause button measurement mode 14 protective insert Technical specifications of the Receiver are listed...

Страница 4: ...axis Check the charge status of the batteries the charge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol i...

Страница 5: ...in the spots where the signal level is the highest 7 We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the...

Страница 6: ...er to enter the review mode 1 Turn off measurement mode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launc...

Страница 7: ...alid signal and lowest number of light stripes interference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the su...

Страница 8: ...ected modes and parameters animated scale for input signal level numeric value and animated scale of output signal level graph moving diagram of the output signal level output signal frequency spectru...

Страница 9: ...ed battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with...

Страница 10: ...output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central freq...

Страница 11: ...lue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the...

Страница 12: ...can be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of...

Страница 13: ...y natural sound is used When working with EMD in the mode natural sound to the phones the adopted highactive frequency8192Hzand33kHz beforeplaying areconvertedintoawell acceptable low frequencies of 8...

Отзывы: