30
DEVELOPMENT, MANUFACTURING AND SUPPLY OF INSTRUMENTATION
5.. Approach.the.supposed.place.of.cable.route,.on.which.the.signal.from.the.generator.was..
transmitted..Locate.the.receiver.axis.in.parallel.to.the.utility.axis..
The.graph.showing.the.change.in.the.signal.level.will.be.displayed.on.the.screen.in.frequency.
1.kHz,..on.the.2D.image.of.the.route.of.the.cable.located.near.(if.any).will.be.displayed.under.the.
voltage.50(60)Hz.
You.should.move.the.receiver.as.shown.on.the.figure.
The.place.of.the.crossing.of.the.cable.corresponds.to.the.setting.of.the.pointer.“50.Hz”.onto.
the.centre.of.the.circle.at.maximum.value.of.the.indication.on.the.“Graph”.of.the.active.frequency.
signal..
Utility.axis.“50.Hz”..
is.in.the.centre
Utility.axis.“1..kHz”
.is.determined.
on.the..maximum.level.
of.the.signal..on.the.graphic
Cable.under.voltage..50(60).Hz
operator.movement.
direction
cables.with.the.induced.
signal.1,0kHz.from.the.
generator
Содержание AG-309.15G