background image

Low Battery Indicator 

 

Replace  the  4  AA  Alkaline  batteries  when  the  red  LED  on  the 
control panel is lit.  Follow battery installation instructions under 

Maintenance

 section. 

 

Audio Mute Function 

 

To  silence  or  mute  the  audio  beep  and  alarm  signal,  press  the 
MUTE  button.  To  restore  the  audio  sound,  press  the  MUTE 
button again. (Note: a few seconds is required to restore sound 
if the mute button is pressed in rapid succession.) 

 

 
 
 
 

 
 
 
 
 
 
 
 
 

Cross Sensitivity to Automotive Chemicals

 

Some  automotive  solvents  and  chemicals  have  similar  hydrocarbon 
properties  as  H2  and  may  elicit  a  positive  response  (<20  seconds) 
from the D740. Before leak checking, clean up any chemicals in the list 
below that elicit a positive response. 

 
 
 
 
 
 
 
 
 
 

 

Product Specifications 

 

Model  # 

D740 

Name 

Leak Detector, H2 Tracer Gas 

Sensitivity 

4 g/yr R-134a equivalent 

Sensor Life 

>300 hours 

Response Time 

Instantaneous 

Power Supply 

4 AA Alkaline batteries 

Battery Life 

4-6 hours continuous 

Warm up time 

< 20 seconds 

Probe length 

17 inches 

Numerical Display 

7 segment digital display (1 to 9) 

Weight, lbs 

1.5 lbs 

Warranty 

2 years  

 
 

Chemical Name/Brand 

Response 

Methanol based windshield wash fluid 

Ford Spot Remover (Wet) 

Ford Rust Inhibitor 

Ford Gasket Adhesive (Wet) 

Loctite Natural Blue degreaser (diluted) 

Ford Brake Parts Cleaner 

Ford Silicone Rubber (uncured) 

Motorcraft Antifreeze heated to 160 deg F 

Gunk liquid wrench 

Ford silicone lubricant 

Ford Pumice lotion (with solvent) 

Ford Motorcraft brake fluid  

Ford Carburetor Cleaner 

Transmission fluid heated to 160 deg F 

Mineral engine oil heated to 160 deg F 

 

Содержание D740

Страница 1: ...Model D740 H2 Tracer Gas Leak Detector User Manual Detects H2 N2 5 95 Tracer Gas Design certified by ACSI to meet SAE Standard J2970...

Страница 2: ...4a in the HI setting and 7 g yr in the NORM setting while moving the probe at 3 second This complies with SAE Standard J2970 sections 7 2 and 7 3 Leak Testing with Tracer Gas is consistent with the te...

Страница 3: ...long a c lines and fittings no further away than 3 8 and moving at approximately 3 second If the detector alarms make smaller sweeps back and forth until the leak source can be pin pointed Note The D7...

Страница 4: ...ate of approximately 3 second and as close as possible to the suspected area If looking for an apparently larger leak check first at the 7 g yr Norm setting or the LO setting Once the source of the le...

Страница 5: ...in the center of the screw cap to expose the vent hole in the top of the screw cap see fig below 2 Turn on the detector and allow the unit to complete the warm up cycle 3 Place the sensor close to th...

Страница 6: ...er battery orientation Sensor Replace Filter Unscrew sensor tip as shown to replace filter Replace filter whenever it becomes visibly dirty or every 2 to 3 months depending on use Replace Sensor Remov...

Страница 7: ...itive response Product Specifications Model D740 Name Leak Detector H2 Tracer Gas Sensitivity 4 g yr R 134a equivalent Sensor Life 300 hours Response Time Instantaneous Power Supply 4 AA Alkaline batt...

Страница 8: ...with return address phone number and or email address SERVICE CENTER 2651 W 81st Street Hialeah FL33016 WARRANTY POLICY The D740H2 N2 Tracer Gas Leak Detector is warranted to be free of defects in ma...

Отзывы: