Proline Promass F 500 EtherNet/IP
Installation
27
1
2
A0028774
7
Orientation of sensor with curved measuring tube
1
Avoid this orientation for fluids with entrained solids: Risk of solids accumulating.
2
Avoid this orientation for outgassing fluids: Risk of gas accumulating.
Inlet and outlet runs
No special precautions need to be taken for fittings which create turbulence, such as
valves, elbows or T-pieces, as long as no cavitation occurs → 28.
A0029322
A0029323
Installation dimensions
For the dimensions and installation lengths of the device, see the "Technical
Information" document, "Mechanical construction" section.
6.1.2
Requirements from environment and process
Ambient temperature range
Measuring device
• –40 to +60 °C (–40 to +140 °F)
• Order code for "Test, certificate", option
JP
:
–50 to +60 °C (–58 to +140 °F)
• Order code for "Test, certificate", option
JQ
:
– Sensor:–60 to +60 °C (–76 to +140 °F)
– Transmitter: –50 to +60 °C (–58 to +140 °F)
Readability of the
local display
–20 to +60 °C (–4 to +140 °F)
The readability of the display may be impaired at temperatures outside the temperature
range.
Dependency of ambient temperature on medium temperature→ 268
‣
If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.
You can order a weather protection cover from Hauser : → 247