OPERATIONS GUIDE

•  Turn on the power switch located on the right side of the machine. 

Wait for the machine to display the input screen.

•  You can press the Help button from any screen for more 

information about that screen’s functions.

POWERING UP THE MACHINE

•  Choose the toolholder seat that corresponds with your toolholder.  

Place the seat over the pedestal hole and insert your toolholder.

•  Choose the induction stop ring. Place the stop ring into the 

induction head, rotate it 90˚ to secure its position. Press the “Auto 
Up” button on the touch screen.

•  From the main screen, select your tool shank size. You can switch 

between inch or millimeter using the setup screen.

INSERTING YOUR CUTTING TOOL

Use the drop 
down menu to
choose your 
shank size 

Touch units to 
switch between 
inches or metric

Induction stop ring

•  Machine requires a level, stable surface and good ventilation for 

proper operation. Keep the machine clean and dry at all times.

•  Connect the machine to your power supply. The machine operates 

on 480V on a 3-phase 20 amp circuit.

•  ANEMA L8-20P plug comes installed on the power cord. Requires 

NEMA L8-20R recepticle.

•  Connect the source air line to machine’s air inlet (90 psi required). 

MACHINE SETUP

Always inspect your cutting tool for any imperfec-
tions on the shank such as chips, burrs, or scar-
ring. If you find any, do not use that cutting tool 
in a shrink-fit toolholder, or it may no be able to 
remove it. The ability to insert and remove tools is 
enhanced when cutting tools and holders are dry 
and clean.

VERIFYING PROPER INSTALLATION

•  Turn the power switch clockwise to turn on the machine. Wait as 

your machine powers up and displays the input screen.

•   Touch the “Head Air On” button to test the Air connection.  “Head 

Air Off” to cancel.

•  Your ShrinkSTATION is now ready for use.

Содержание 00450

Страница 1: ...TIONS MANUAL Techniks Inc 9930 E 56th St Indianapolis IN 46236 800 597 3921 www techniksusa com info techniksusa com Techniks is a proud member of Techniks Tool Group Connect with Techniks Tool Group COMPLETE INSTALLATION AND TROUBLESHOOTING GUIDE ...

Страница 2: ...tion build up from causing electronic system errors Persons with heart pacemakers may not operate the machine and must maintain a minimum safe distance of 6 feet 2 meters from the machine at all times Cutting tools have sharp edges Handle with caution The power cord provided must be plugged into the correct NEMA L16 20R outlet Operating the unit while improperly connected or at the wrong voltage m...

Страница 3: ... ShrinkSTATION machines are designed to work best with Techniks shrink fit tool holders made from H13 tool steel with bore diameters from 1 8 to 1 1 4 3mm to 32mm They are designed for shrink fitting tools with carbide shanks Tool shank diameter tolerance is critical At least an H6 tolerance is advised for optimum performance Make sure toolholders are clean and free from defects before inserting t...

Страница 4: ...e and ease of use in demanding environments The ShrinkSTATION includes everything you need to perform shrink fit tool changes on CAT40 CAT50 BT30 BT40 ISO30 HSK40 50 63 and 100 C4 C5 C6 toolholders with gauge lengths up to 22 560mm TOUCH SCREEN CAPABILITIES Jog Speed The speed of the tool holder during manual movement Auto Up Speed The speed of the tool holder during automated movement toward the ...

Страница 5: ...ts to switch between inches or metric Induction stop ring Machine requires a level stable surface and good ventilation for proper operation Keep the machine clean and dry at all times Connect the machine to your power supply The machine operates on 480V on a 3 phase 20 amp circuit ANEMA L8 20P plug comes installed on the power cord Requires NEMA L8 20R recepticle Connect the source air line to mac...

Страница 6: ...utton throughout the heating cycle Approximately 2 or 3 seconds before the heating cycle ends attempt to remove the cutting tool from the toolholder with the gloved hand If the tool cannot be extracted on the first try cool the tool to room temperature and increase the heating duration by 10 and try again The heating cycle will stop automatically at the end of the set duration Heating duration is ...

Отзывы: