Technifab Products Cryogenic Tank Switcher Скачать руководство пользователя страница 9

LT-33020(2) 

©2013 Technifab Products, Inc. 

Maximum Pressure 

30 psig (2.0 Bar) 

Manifold Dimensions 

(2 Tank Version) 

29.5” wide x 29” high x 23” deep  

(75 cm x 74 cm x 59 cm) 

Control Box Dimensions 

11.5” wide x 13.5” high x 6” deep 

(29.2 cm x  34.3 cm x  15 cm) 

Control Box Operating Temperature 

32°F - 122°F (0°C - 50°C) 

Enclosure and Penetrations Rating 

NEMA 4X, IP65 

Power Requirements 

110-240 VAC, 50-60 Hz

Power Usage 

200 watts @ 110 VAC nominal 

1.7 amp maximum 

Alarm Output 

24 VDC 

0.2 amp max current 

Product Specific

ations 

Technifab Cryogenic Tank Switcher 

Support Information 

Technifab continuously seeks to improve its products. Customer feedback 
is an essential element of this process. Should any issue arise regarding 
this product’s performance, please immediately notify: 

Technifab Products, Inc. - Quality Department 

812.442.0520 

 10339 

N. 

Industrial 

Park 

Drive 

812.442.0891 

Fax 

 P.O. 

Box 

315 

 

[email protected] 

 Brazil, 

Indiana 

47834 

USA 

 

www.technifab.com 

Distributed by PrincetonCryo.com | 800-232-2796 | [email protected]

Содержание Cryogenic Tank Switcher

Страница 1: ...LT 33020 2 2013 Technifab Products Inc 1 Technifab Vacuum Jacketed Tank Switcher Installation Manual...

Страница 2: ...013 Symbols Used in this Manual Warning indicates a potentially hazardous situation which if not avoided could result in death or serious injury Caution indicates a potentially hazardous situation whi...

Страница 3: ...chnifab Products Inc recommends routing the discharge lines from pressure relief devices to a safe place of discharge The outlet of the discharge line should not be in a location where it could injure...

Страница 4: ...her Manifold Assembly with Junction Box Note Most tank switchers include a cryogenic inlet filter installed inside the inlet female bayonets You should use an orange colored bayonet clamp two shown to...

Страница 5: ...ld be large enough to support the manifold The photo shows an example of a well mounted tank assembly Be sure to mount the manifold in three places shown with arrows on in the photo one clamp on each...

Страница 6: ...cables are connected on the right side from the bottom up 6 Hookup the inlet and outlet piping to the manifold If the tank switcher inlets have inline cryogenic filters be sure to use the supplied ora...

Страница 7: ...econfigured at the factory For shop air the Pneumatic Actuated Valve Guidelines Technifab part number literature LT 35569 has a more complete description of the differences and shop air requirements F...

Страница 8: ...deliver liquid nitrogen Press the onscreen Run Stop button press the onscreen reset button and press the Run Stop button again A longer Switcher Timer SP setting may be necessary Error message on scre...

Страница 9: ...tts 110 VAC nominal 1 7 amp maximum Alarm Output 24 VDC 0 2 amp max current Product Specifications Technifab Cryogenic Tank Switcher Support Information Technifab continuously seeks to improve its pro...

Отзывы: