![Technics RS-DV250 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/technics/rs-dv250/rs-dv250_service-manual_1068280005.webp)
http://servis-manual.com/
5.3 Deck 1 mechanism check
TOP
PREVIOUS
NEXT
1. Press the Deck 1/deck 2 select button to change the flashing Deck 2 indicator to Deck 1. Refer
to
Fig. 5-2.
/(No change required if Deck 1 indicator already flashing.)
2. Press the Deck 1 cassette holder open button to open the Deck 1 cassette holder. Refer to
Fig.
5-2.
3. Insert a CrO2 tape into the Deck 1 and close the cassette holder.
4. Press the Fast forward button. Refer to
Fig. 5-2.
/(Tape fast forwards for about 2 seconds then
stops.)
5. Press the PLAY button. Refer to
Fig. 5-2.
/(After TPS operation and check, the tape stops.)
6. Open the Deck 1 cassette holder and replace the tape with a normal tape.
7. Close the Deck 1 cassette holder.
8. Press the Record pause button. Refer to
Fig. 5-2.
/(No record operation.)
9. Press the STOP button. Refer to
Fig. 5-2.
A mechanism error code is displayed. Refer to Table
5-1. Each time the STOP button is pressed, the fault items are displayed in sequence.
Fig. 5-2.
Table 5-1.
FL
display
Symptom
Cause
H01
Cassette deck does not operate correctly.
Faulty cassette deck mechanism mode detect switch (Deck 1: S951,
Deck 2: S971), plunger and capstan motor. /(Check and replace)
H02
Unit does not record or the unit goes into recording mode even when the
erasure prevention tabs have been removed from the cassette.
Faulty erasure prevention tabs detect switch (S974, S975) or short-
circuit. (Check and replace)
H03
Tape does not play even when the tape deck play button is pressed.
The motor operates when the tape deck play button is pressed even if
cassette is loaded in the deck.
Faulty tape detect switch (Deck 1: S952 Deck 2: S972) or short-circuit.
(Check and replace)
H06
Cassette deck does not detect CrO2 tape.
Faulty CrO2 tape detect switch (Deck 1: S953, Deck 2: S973)./(Check
and replace)
H07
Cassette deck does not detect Metal tape.
Faulty Metal tape detect switch (S976). (Check and replace)
F01
When the tape play button is pressed, tape advances only slightly and
then stops.
Reel pulse error (Faulty Hall IC). (Check and replace)
F02
TPS (tape program search) does not work.
Faulty TPS signal detection or faulty plunger control. /(Check and
replace mechanism control IC)
20. 10. 2004