    What is DMX: 

There are 512 channels in a DMX connection. Channels may be assigned in any manner. A fixture capable of 
receiving DMX will require one or a number of sequential channels. The user must assign a starting address 
on the fixture that indicates the first channel reserved in the controller. There are many different types of DMX 
controllable fixtures and they all may vary in the total number of channels required. Choosing a start address 
should be planned in advance. Channels should never overlap. If they do, this will result in erratic operation 
of the fixtures whose starting address is set incorrectly. You can however, control multiple fixtures of the 
same type using the same starting address as long as the intended result is that of unison movement or 
operation. In other words, the fixtures will be slaved together and all respond exactly the same.   
DMX fixtures are designed to receive data through a serial Daisy Chain. A Daisy Chain connection is where 
the DATA OUT of one fixture connects to the DATA IN of the next fixture. The order in which the fixtures are 
connected is not important and has no effect on how a controller communicates to each fixture. Use an order 
that provides for the easiest and most direct cabling. Connect fixtures using shielded two conductor twisted 
pair cable with three pin XLR male to female connectors. The shield connection is pin 1, while pin 2 is Data 
Negative (S-) and pin 3 is Data positive (S+).   

 

Maintaining the Fixture:

 

 

To maintain optimum performance and minimize wear, fixtures should be cleaned frequently. Usage and 
environment are contributing factors in determining frequency. As a general rule, fixtures should be cleaned 
at least twice a month. Dust build up reduces light output performance and can cause overheating. This can 
lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting 
maintenance.   
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust collected on 
external vents.    Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl 
Alcohol and a soft lint free cotton cloth or lens tissue.    Apply solution to the cloth or tissue and drag dirt and 
grime to the outside of the lens. Gently polish optical surfaces until they are free of haze and lint.   
The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light 
output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky or 
particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. Clean with soft 
cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. Clean the fixture at 
least every 30/60 days. Always dry the parts carefully after cleaning them. Never spin a fan using compressed 
air. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

LG500x 

Содержание LG500x

Страница 1: ...User Manual for Professional DJ Multicolor LED Stage Effect light With DMX MODEL LG500x...

Страница 2: ...disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source 15 Secure fixture to fastening device using a safety chain 16 Maximum ambient temperature...

Страница 3: ...e this knob to adjust the sensitivity of the lights when the fixture is operating in sound activated mode 4 DMX Output XLR DMX Digital Multiplex is the form of communication between controller and fix...

Страница 4: ...erage current draw under normal conditions Always connect the fixture to a circuit with a suitable electrical ground The AC power cords supplied purposefully have 2 blades and one grounding prong If y...

Страница 5: ...to female connectors The shield connection is pin 1 while pin 2 is Data Negative S and pin 3 is Data positive S Maintaining the Fixture To maintain optimum performance and minimize wear fixtures shoul...

Страница 6: ...3 If 7 is on it is Sound Activated mode 4 If 8 is on it is Auto pilot mode it will output all the built in programs 5 If 1 are on it is DMX mode the CH1 of the lights will start from the first channe...

Страница 7: ...1 of the DMX controller to be the CH1 of the special lights Then the Channel 2 in the DMX controller as the CH2 to control the lights and so on IF 2 on it means to use the Channel 2 of the DMX contro...

Страница 8: ...on IF 7 on it means to use the Channel 64 of the DMX controller to be the CH1 of a special lights Then the next channel 65 of the DMX controller as the CH2 to control the lights and so on IF 8 on it...

Страница 9: ...e lights and so on IF 4 and 5 on it is 8 16 24 it means to use the Channel 24 of the DMX controller to be the CH1 of a special lights then the next channel 25 of the DMX controller as the CH2 to contr...

Страница 10: ...ferent effect DMX512 Function Channel Value Function CH1 0 199 Speed Connect with CH2 3 4 5 6 7 8 32 200 249 Auto pilot 255 Sound Activated CH2 3 4 5 6 7 8 each channel control one separate LED area t...

Страница 11: ...469pcs red 280 Green 63 Blue 126 System Port DMX512 input and output port Control Mode Auto Sound Active DMX512 Demo Effect 255 grade high brightness level 0 100 linear dimming Power Supply AC110V Pow...