background image

4

Installation Location

• We recommend that this air conditioner be installed properly by 

qualified installation technicians in accordance with the Installation 
Instructions provided with the unit.

Before installation, check that the voltage of the electric supply in your home 
or office is the same as the voltage shown on the nameplate.

Electrical Requirements

1.

All wiring must conform to the local electrical codes. Consult your dealer or a 
qualified electrician for details.

2.

Each unit must be properly grounded with a ground (or earth) wire or 
through the supply wiring.

3.

Wiring must be done by a qualified electrician.

Safety Instructions

• Read this Instruction Manual carefully before using this air 

conditioner. If you still have any difficulties or problems, consult your 
dealer for help.

• This air conditioner is designed to give you comfortable room 

conditions. Use this only for its intended purpose as described in this 
Instruction Manual.

• Do not install this air conditioner where there are fumes or 

flammable gases, or in an extremely humid space such as a 
greenhouse.

• Do not install the air conditioner where excessively high heat-

generating objects are placed.

Avoid:

To protect the air conditioner from heavy corrosion, avoid installing the 
outdoor unit where salty sea water can splash directly onto it or in 
sulphurous air near a spa.

• Never use or store gasoline or other flammable vapor or liquid near 

the air conditioner — it is very dangerous.

• This air conditioner has no ventilator for intaking fresh air from 

outdoors. You must open doors or windows frequently when you 
use gas or oil heating appliances in the same room, which consume 
a lot of oxygen from the air. Otherwise there is a risk of suffocation 
in an extreme case.

• Do not turn the air conditioner on and off from the power mains 

switch. Use the ON/OFF operation button.

• Do not stick anything into the air outlet of the outdoor unit. This is 

dangerous because the fan is rotating at high speed.

• Do not let children play with the air conditioner.
• Do not cool or heat the room too much if babies or invalids are 

present.

CAUTION

OI-047-4-EG

01_MCAF78MR5I_EN.fm  Page 4  Friday, November 2, 2007  2:28 PM

Содержание MCAF128MR5I

Страница 1: ...ida sistema split Climatiseurs split Split klimager t Condizionatore d aria split system Save These Instructions Guard is estas instrucciones Conserver ce notice d utilisation Bewahren Sie bitte diese...

Страница 2: ...around the room and providing comfort in every corner Auto Flap Control This automatically sets the flap to the optimum position during heating cooling and drying operation Hot Start Heating System R...

Страница 3: ...te on the bottom of the cabinet Model No ______________________ Serial No ____________________ Date of purchase ________________________________________________ Dealer s address ______________________...

Страница 4: ...where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generating objects are placed Avoid To prote...

Страница 5: ...r through the air outlet Remote Control Unit The wireless remote control unit controls power ON OFF operation mode selection temperature fan speed timer setting and air sweeping Refrigerant Tubes The...

Страница 6: ...lternately when the system is defrosting TIMER lamp This lamp lights when the system is being controlled by the timer QUIET lamp This lamp lights during operation in the QUIET mode ION lamp This lamp...

Страница 7: ...NIGHT SETBACK 6 Confirmation of transmission 7 Auto flap indication Flap angle indication Sweep indication 8 High power operation 9 Quiet operation 10 ION operation Displayed when setting timer Displa...

Страница 8: ...uttons on the remote control unit the mark appears in the display to transmit the setting changes to the receiver in the air conditioner Sensor A temperature sensor inside the remote control unit sens...

Страница 9: ...in the HEAT DRY or COOL mode the mark appears in the display and the remote control unit will automatically adjust the set temperature to save energy FLAP button Press this button either to select the...

Страница 10: ...l unit sends the temperature signal to the air conditioner regularly at five minute intervals If the signal from the remote control unit stops for more than 15 minutes due to the loss of the remote co...

Страница 11: ...5 minutes Mounting the Remote Control Unit Before mounting the remote control unit press the ON OFF operation button at the mounting location to make sure that the air conditioner operates from that l...

Страница 12: ...following the steps below you can have the air conditioner automatically bring the room to the desired temperature simply by pressing the ON OFF operation button STEP 1 Press the MODE selector button...

Страница 13: ...P 3 Press the TEMP setting buttons to change the temperature setting to the desired temperature Adjustable temperature range STEP 4 Set the FAN SPEED selector button to the setting you want STEP 5 Pre...

Страница 14: ...nsure reliable operation When the operation button is pressed the compressor will start running within three minutes In the event of power failure the unit will stop 3 Adjusting the Fan Speed A Automa...

Страница 15: ...etback was selected This enables you to save energy without sacrificing comfort This function is convenient when gentle cooling is needed Setting temperature Press the NIGHT SETBACK button 30 min 30 m...

Страница 16: ...mum output for 30 minutes regardless of the desired temperature The fan speed is 1 step above High HIGH POWER Mode cannot be used when the operation mode is Automatic Operation QUIET Mode and HIGH POW...

Страница 17: ...eating operation restarts after several minutes This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms Cold draft prevention For several minutes after...

Страница 18: ...displayed The time can be set in 1 minute increments Holding down the button advances the time rapidly in 10 minute increments 3 Press the CLOCK button again This completes the setting of the current...

Страница 19: ...ff Operation Indication 1 Press the ON TIME setting button once The timer indication is displayed and the present ON time is shown 2 Press the Advance Return button until AM 7 10 is displayed The time...

Страница 20: ...at point in time and then stops It is not possible to use the OFF Timer and 1 Hour OFF Timer together Whichever function is set last takes precedence If the 1 HR TIMER button is pressed while the TIME...

Страница 21: ...ng blown out of the unit begins to warm Once the air warms up the flap position and fan speed change to the settings specified with the remote control Use the FLAP button on the remote control to adju...

Страница 22: ...oor unit to clean it This will damage the internal components and cause an electric shock hazard Casing and Grille Indoor Unit Clean the casing and grille of the indoor unit with a vacuum cleaner brus...

Страница 23: ...ld filter 1 With the FRONT mark of the anti mold filter at the front align the two indentions near the mark with the hooks at the rear of the air intake grille and then mount the anti mold filter 2 Al...

Страница 24: ...h in warm water no hotter than 40 C wring thoroughly and then wipe The air intake grille can be removed in order to wash it with water Removing and remounting the air intake grille Refer to How to rem...

Страница 25: ...eat source if possible 3 Doors and or windows are open 3 Shut them to keep the heat or cold out 4 Obstacle near air intake or air discharge port 4 Remove it to ensure good airflow 5 Thermostat is set...

Страница 26: ...rappeler l obligation d liminer s par ment ces quipements le produit porte le symbole d un caisson ordures barr HINWEIS F R DIE KORREKTE ENTSORGUNG DES PRODUKTS IN BEREINSTIMMUNG MIT DER EUROP ISCHEN...

Страница 27: ...123...

Страница 28: ...R D 28 Reyrieux BP 131 01601 Tr voux CEDEX France Tel 33 04 74 00 92 92 Fax 33 04 74 00 42 00 http www technibel com...

Страница 29: ...e protocole de Kyoto avec un potentiel de chauffage global GWP 1975 Zerstreuen Sie R410A in Atmosph re nicht R410A ist ein fluoriertes Gas abgedeckt durch Kyoto Protokoll mit einem globalen w rmenden...